Specials

All specials

AS/NZS 1972:2006

AS/NZS 1972:2006

Electric cables - Underground coal mines - Other than reeling and trailing

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Table of Contents

1 -  AS/NZS 1972:2006 ELECTRIC CABLES-UNDERGROUND COAL MINES-OTHER THAN REELING AND TRAILING
4 -  PREFACE
5 -  CONTENTS
7 -  SECTION 1 SCOPE AND GENERAL
7 -  1.1 SCOPE
7 -  1.2 APPLICATION
8 -  1.3 REFERENCED DOCUMENTS
8 -  1.4 DEFINITIONS
8 -  1.4.1 Communications circuit assembly
8 -  1.4.2 Electrically symmetrical
9 -  1.4.3 Non°hygroscopic
9 -  1.4.4 Pitch circle diameter
9 -  1.4.5 Shall
9 -  1.4.6 Should
9 -  1.4.7 Support member
9 -  1.4.8 Suspended length
9 -  1.4.9 Voltage designation
10 -  SECTION 2 0.6/1 (1.2) kV CABLES FOR FIXED APPARATUS
10 -  2.1 SCOPE OF SECTION
10 -  2.2 DESIGN
10 -  2.3 CONSTRUCTION
11 -  2.4 CONDUCTORS
11 -  2.5 FILLERS
11 -  2.6 SCREENS
11 -  2.6.1 General
11 -  2.6.2 Conductance
11 -  2.6.3 Additional requirement for cables with individually screened cores
11 -  2.7 COLLECTIVE TAPE SCREEN
11 -  2.7.1 General
12 -  2.7.2 Conductance
12 -  2.8 ARMOUR
12 -  2.8.1 Type of armour
12 -  2.8.2 Conductance
12 -  2.9 TESTS
13 -  SECTION 3 ARMOURED CABLES FOR USE AT WORKING VOLTAGES OF 1.9/3.3 (3.6) kV UP TO AND INCLUDING 19/33 (36) kV
13 -  3.1 SCOPE OF SECTION
13 -  3.2 CONDUCTORS
13 -  3.3 SCREENS FOR CABLES MANUFACTURED IN ACCORDANCE WITH AS/NZS 1429.1
13 -  3.3.1 General
13 -  3.3.2 Conductance
13 -  3.4 ARMOUR FOR CABLES MANUFACTURED IN ACCORDANCE WITH AS/NZS 1026
13 -  3.4.1 Type of armour
13 -  3.4.2 Conductance
14 -  3.5 OUTER SHEATH
14 -  3.6 MARKING
14 -  3.7 TESTS
15 -  SECTION 4 FEEDER CABLES
15 -  4.1 SCOPE OF SECTION
15 -  4.2 TYPES OF CABLES
15 -  4.3 CONSTRUCTION
15 -  4.3.1 Type A feeder cables
15 -  4.3.2 Type B feeder cables
15 -  4.4 CONDUCTORS
15 -  4.5 INSULATION
15 -  4.5.1 Material
16 -  4.5.2 Thickness
16 -  4.6 SCREENS
16 -  4.6.1 Construction
16 -  4.6.2 Coverage
16 -  4.6.3 Conductance
16 -  4.7 COVERING ON PILOT CORES
16 -  4.7.1 Material
17 -  4.7.2 Thickness
17 -  4.8 LAYING UP OF CORES
17 -  4.9 SHEATH
17 -  4.9.1 Material and application
17 -  4.9.2 Thickness
17 -  4.10 EXTERNAL MARKING OF CABLE
18 -  4.11 TESTS
19 -  SECTION 5 MACHINE CABLES
19 -  5.1 SCOPE OF SECTION
19 -  5.2 TYPES
20 -  5.3 DIMENSIONS FOR MACHINE CABLES
20 -  5.4 TYPE 1
20 -  5.4.1 Design
20 -  5.4.2 Conductors
20 -  5.4.3 Insulation
21 -  5.4.4 Screens
22 -  5.4.5 Fillers
22 -  5.4.6 Covering
22 -  5.4.7 Tests
22 -  5.5 TYPES 2 AND 2S
22 -  5.5.1 Design
22 -  5.5.2 Conductors
23 -  5.5.3 Semiconductive screens for 3.3/3.3 kV cables
23 -  5.5.4 Insulation
23 -  5.5.5 Screens
23 -  5.5.6 Fillers
23 -  5.5.7 Covering-Type 2 cables only
23 -  5.5.8 Sheath-Type 2S cables only
23 -  5.5.9 Pilot and control conductors
24 -  0 10 Tests
24 -  5.6 TYPES 3 AND 3S
24 -  5.6.1 Application
24 -  5.6.2 Design
24 -  5.6.3 Conductors
24 -  5.6.4 Insulation
24 -  5.6.5 Screens
24 -  5.6.6 Fillers
24 -  5.6.7 Covering-Type 3 cables only
25 -  5.6.8 Sheath-Type 3S cables only
25 -  5.6.9 Pilot conductor
25 -  5.6.10 Tests
25 -  5.7 TYPES 7 AND 7S
25 -  5.7.1 Conductors
25 -  5.7.2 Glass braid
25 -  5.7.3 Insulation
26 -  5.7.4 Screen
26 -  5.7.5 Covering-Type 7 cables only
26 -  5.7.6 Sheath-Type 7S cables only
26 -  5.7.7 Tests
26 -  5.8 TYPE 8
26 -  5.8.1 Design
26 -  5.8.2 Conductors
26 -  5.8.3 Insulation
27 -  5.8.4 Screens
27 -  5.8.5 Fillers
27 -  5.8.6 Pilot conductors
27 -  5.8.7 Covering
27 -  5.8.8 Tests
27 -  5.9 TYPE 9
27 -  5.9.1 Design
27 -  5.9.2 Conductors
27 -  5.9.3 Insulation
27 -  5.9.4 Core identification
27 -  5.9.5 Pairs and triads
28 -  5.9.6 Screens
28 -  5.9.7 Fillers
28 -  5.9.8 Covering
28 -  5.9.9 Tests
28 -  5.10 MARKING
28 -  5.10.1 Marking on cables
28 -  5.10.2 Marking of drums
30 -  SECTION 6 MINE SHAFT WINDER CABLES
30 -  6.1 SCOPE OF SECTION
30 -  6.2 DESIGN
30 -  6.3 CONDUCTORS
30 -  6.4 INSULATION
30 -  6.5 TEXTILE BRAIDING OVER CORES
31 -  6.6 CORE IDENTIFICATION
31 -  6.7 SCREENED COMMUNICATION CORES
31 -  6.8 SUPPORT MEMBERS
32 -  6.9 FILLERS AND BINDERS
32 -  6.10 LAY-UP OF CABLE CORES
32 -  6.11 TEXTILE BRAID OVER LAID-UP CORE ASSEMBLY
32 -  6.12 SHEATH
32 -  6.12.1 Material
32 -  6.12.2 Thickness
33 -  6.13 SUSPENDED LENGTHS
33 -  6.14 MARKING
33 -  6.14.1 Marking on cables
33 -  6.14.2 Marking of drums
33 -  6.15 TESTS
33 -  6.15.1 General
35 -  6.15.2 High voltage test on completed cable
35 -  6.15.3 Flexing test
37 -  APPENDIX A - INFORMATION TO BE SUPPLIED WITH ENQUIRY AND ORDER
38 -  APPENDIX B - RECOMMENDATIONS FOR THE SELECTION OF PAPER, OR POLYMERIC INSULATED CABLES
38 -  B1 SCOPE
38 -  B2 SYSTEM CATEGORIES
38 -  B3 CABLE SELECTION
40 -  APPENDIX C - TABLES OF DIMENSIONS FOR MACHINE CABLES
43 -  APPENDIX D - CALCULATION OF SUSPENDED LENGTHS FOR CABLES

Abstract

Specifies the construction of cables for fixed apparatus, armoured high voltage cables, feeder cables, machine cables and mine shaft winder cables for underground use in coal mines.

Scope

This Standard specifies the construction of cables used in underground coal mines.
This Standard does not apply to reeling and trailing cables, which are covered by AS/NZS 1802, cables for use in IS circuits and data, communication and control cables unless specifically covered.
NOTE: Guidelines on information that should be supplied with enquiries or orders are provided in Appendix A.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
Committee EL-003
Supersedes
  • DR 05187
  • AS/NZS 1972:2002

Contact us