Specials

All specials

IEC 61347-2-3 : 2.1

IEC 61347-2-3 : 2.1

LAMP CONTROL GEAR - PART 2-3: PARTICULAR REQUIREMENTS FOR A.C. AND/OR D.C. SUPPLIED ELECTRONIC CONTROL GEAR FOR FLUORESCENT LAMPS

International Electrotechnical Committee

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Table of Contents

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Classification
7 Marking
8 Protection against accidental contact with live
   parts
9 Terminals
10 Provisions for earthing
11 Moisture resistance and insulation
12 Electric strength
13 Thermal endurance test for windings
14 Fault conditions
15 Protection of associated components
16 Abnormal conditions
17 Behaviour of the control gear at end of lamp life
18 Construction
19 Creepage distances and clearances
20 Screws, current-carrying parts and connections
21 Resistance to heat, fire and tracking
22 Resistance to corrosion
Annex A (normative) - Test to establish whether a conductive
        part is a live part which may cause an electric shock
Annex B (normative) - Particular requirements for thermally
        protected lamp control gear
Annex C (normative) - Particular requirements for electronic
        lamp control gear with means of protection against
        overheating
Annex D (normative) - Requirements for carrying out the
        heating tests of thermally protected lamp control gear
Annex E (normative) - Use of constant S other than 4500
        in t[w] tests
Annex F (normative) - Draught-proof enclosure
Annex G (normative) - Explanation of the derivation of the
        values of pulse voltages
Annex H (normative) Tests
Annex I (normative) - Measurement of high-frequency
        leakage current
Annex J (normative) - Particular additional safety
        requirements for a.c., a.c./d.c. or d.c supplied
        electronic control gear for emergency lighting
Annex K (informative) - Components used in the
        asymmetric pulse test circuit
Annex L (normative) - Information for control gear design
       (from Annex E of IEC 61195)
Bibliography

Abstract

Describes particular safety requirements for electronic control gear for use on a.c. supplies at 50 Hz or 60 Hz up to 1000 V and/or d.c. supplies up to 1000 V with lamp operating frequencies deviating from the supply frequency, associated with fluorescent lamps as specified in IEC 60081 and IEC 60901, and other fluorescent lamps for high-frequency operation.

General Product Information

Document Type Standard
Status Current
Publisher International Electrotechnical Committee
Committee TC 34

Contact us