IEC 60353 : 2.0
IEC 60353 : 2.0
LINE TRAPS FOR A.C. POWER SYSTEMS
International Electrotechnical Committee
LINE TRAPS FOR A.C. POWER SYSTEMS
International Electrotechnical Committee
FOREWORD<br>PREFACE<br>SECTION ONE - GENERAL<br>Clause<br>1 Scope<br>2 Object<br>3 Symbols used in this standard<br>4 Service conditions<br> 4.1 Standard conditions <br> 4.2 Altitude<br> 4.3 Ambient temperature<br> 4.4 Power frequency <br> 4.5 Wave shape<br> 4.6 Unusual service conditions<br>SECTION TWO - DEFINITIONS<br>5 General <br> 5.1 Main coil <br> 5.2 Tuning device<br> 5.3 Protective device<br> 5.4 Carrier-frequency characteristics<br> 5.5 Currents <br>SECTION THREE - REQUIREMENTS<br>6 General requirements<br> 6.1 Main coil<br> 6.2 Tuning device<br> 6.3 Protective device<br>7 Blocking requirements<br>8 Continuous service requirements<br>9 Ability to withstand rated short-time current <br> 9.1 Mechanical strength <br> 9.2 Thermal behaviour<br>10 Insulation level<br> 10.1 insulation across a line trap<br> 10.2 System voltage insulation <br> 10.3 Line traps for use at high altitudes<br>11 Radio influence voltage (RIV)<br>12 Power losses<br>13 Tensile strength of suspension system<br>14 Accessories<br> 14.1 Bird barriers<br> 14.2 Terminals<br>SECTION FOUR - RATING PLATES<br>15 Rating plate of the main coil<br>16 Rating plate of tuning device<br>17 Rating plate information for protective device<br>SECTION FIVE - TESTS<br>18 General conditions <br>19 Tests<br> 19.1 Temperature rise test (type test)<br> 19.2 Measurement of radio influence voltage (type tests)<br> 19.3 Insulation tests<br> 19.4 Short-time current tests (type tests) <br> 19.5 Measurement of the rated inductance of the main coil<br> (type and routine test)<br> 19.6 Measurement of power frequency inductance of the <br> main coil (type and routine test)<br> 19.7 Measurement of blocking resistance and blocking <br> impedance (type and routine test)<br> 19.8 Measurement of tapping loss and tapping loss based on<br> the blocking resistance (type and routine test) <br>SECTION SIX - RECOMMENDED VALUES<br>20 Rated inductance of main coil (mH) <br>21 Rated continuous current (A) <br>22 Rated short-time current (kA r.m.s.) <br>23 Co-ordination of rated continuous current and rated <br> short-time current<br>APPENDIX A<br>APPENDIX B - Line traps associated with a.c./d.c<br>converter stations<br>Figures
Applies to line traps inserted into high-voltage a.c. transmission lines that prevent undue loss of carrier signal power in the range 30 kHz to 500 kHz under all power system conditions, and that minimize interference from carrier signalling systems on adjacent transmission lines.
Document Type | Standard |
Status | Current |
Publisher | International Electrotechnical Committee |
Committee | TC 57 |