Specials

All specials

IEC 60834-2 : 1.0

IEC 60834-2 : 1.0

PERFORMANCE AND TESTING OF TELEPROTECTION EQUIPMENT OF POWER SYSTEMS - ANALOGUE COMPARISON SYSTEMS

International Electrotechnical Committee

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Table of Contents

FOREWORD<br>Clause<br>SECTION 1: GENERAL<br>1.1 Scope and object<br>1.2 Normative references<br>1.3 Service conditions<br>&nbsp;&nbsp;&nbsp;&nbsp;1.3.1 Ambient conditions<br>&nbsp;&nbsp;&nbsp;&nbsp;1.3.2 Supply voltage with battery operation<br>&nbsp;&nbsp;&nbsp;&nbsp;1.3.3 Supply voltage with a.c. mains operation<br>&nbsp;&nbsp;&nbsp;&nbsp;1.3.4 Storage conditions<br>1.4 Telecommunication system used<br>SECTION 2: TERMINOLOGY<br>SECTION 3: CHARACTERISTIC OF ANALOGUE COMPARISON <br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;TELEPROTECTION SCHEMES<br>3.1 Arrangement of teleprotection schemes and their <br>&nbsp;&nbsp;&nbsp;&nbsp;associated interfaces<br>3.2 Teleprotection operating time<br>3.3 Protection operating time<br>SECTION 4: REQUIREMENTS<br>4.1 General equipment interface requirements<br>&nbsp;&nbsp;&nbsp;&nbsp;4.1.1 Insulation levels<br>&nbsp;&nbsp;&nbsp;&nbsp;4.1.2 Impulse withstand level<br>&nbsp;&nbsp;&nbsp;&nbsp;4.1.3 High frequency disturbance level<br>&nbsp;&nbsp;&nbsp;&nbsp;4.1.4 Specific requirements for interface between <br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;separate protection equipment and teleprotection <br>&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;equipment<br>4.2 Specific power supply requirements<br>&nbsp;&nbsp;&nbsp;&nbsp;4.2.1 Power supply variations<br>&nbsp;&nbsp;&nbsp;&nbsp;4.2.2 Interruptions<br>&nbsp;&nbsp;&nbsp;&nbsp;4.2.3 Reflected noise<br>&nbsp;&nbsp;&nbsp;&nbsp;4.2.4 Reverse polarity<br>4.3 Operational requirements<br>&nbsp;&nbsp;&nbsp;&nbsp;4.3.1 Overall protection requirements<br>&nbsp;&nbsp;&nbsp;&nbsp;4.3.2 Monitoring and alarms<br>SECTION 5: METHODS FOR PERFORMANCE TESTING<br>5.1 General equipment interface tests<br>&nbsp;&nbsp;&nbsp;&nbsp;5.1.1 Insulation tests<br>&nbsp;&nbsp;&nbsp;&nbsp;5.1.2 Impulse withstand test<br>&nbsp;&nbsp;&nbsp;&nbsp;5.1.3 High frequency disturbance test<br>5.2 Specific power supply tests<br>&nbsp;&nbsp;&nbsp;&nbsp;5.2.1 Power supply variations<br>&nbsp;&nbsp;&nbsp;&nbsp;5.2.2 Interruptions<br>&nbsp;&nbsp;&nbsp;&nbsp;5.2.3 Reflected noise<br>&nbsp;&nbsp;&nbsp;&nbsp;5.2.4 Reverse polarity<br>5.3 Teleprotection system performance tests<br>&nbsp;&nbsp;&nbsp;&nbsp;5.3.1 General<br>&nbsp;&nbsp;&nbsp;&nbsp;5.3.2 Procedure<br>&nbsp;&nbsp;&nbsp;&nbsp;5.3.3 Reference condition<br>&nbsp;&nbsp;&nbsp;&nbsp;5.3.4 Current control, monitoring and settings<br>&nbsp;&nbsp;&nbsp;&nbsp;5.3.5 Application of noise to teleprotection channel<br>&nbsp;&nbsp;&nbsp;&nbsp;5.3.6 Dependability<br>&nbsp;&nbsp;&nbsp;&nbsp;5.3.7 Security<br>5.4 Checking alarm functions<br>Figures<br>ANNEXES<br>A Types of analogue comparison protection systems and <br>&nbsp;&nbsp;associated teleprotection schemes<br>B The binary symmetric channel (BSC) model<br>C Bibliography

Abstract

Applies to narrowbank and widebank teleprotection systems used to convey analogue information about the primary quantities such as phase or phase and amplitude.

General Product Information

Document Type Standard
Status Current
Publisher International Electrotechnical Committee
Committee TC 57

Contact us