IEC 60834-2 : 1.0
IEC 60834-2 : 1.0
PERFORMANCE AND TESTING OF TELEPROTECTION EQUIPMENT OF POWER SYSTEMS - ANALOGUE COMPARISON SYSTEMS
International Electrotechnical Committee
PERFORMANCE AND TESTING OF TELEPROTECTION EQUIPMENT OF POWER SYSTEMS - ANALOGUE COMPARISON SYSTEMS
International Electrotechnical Committee
FOREWORD<br>Clause<br>SECTION 1: GENERAL<br>1.1 Scope and object<br>1.2 Normative references<br>1.3 Service conditions<br> 1.3.1 Ambient conditions<br> 1.3.2 Supply voltage with battery operation<br> 1.3.3 Supply voltage with a.c. mains operation<br> 1.3.4 Storage conditions<br>1.4 Telecommunication system used<br>SECTION 2: TERMINOLOGY<br>SECTION 3: CHARACTERISTIC OF ANALOGUE COMPARISON <br> TELEPROTECTION SCHEMES<br>3.1 Arrangement of teleprotection schemes and their <br> associated interfaces<br>3.2 Teleprotection operating time<br>3.3 Protection operating time<br>SECTION 4: REQUIREMENTS<br>4.1 General equipment interface requirements<br> 4.1.1 Insulation levels<br> 4.1.2 Impulse withstand level<br> 4.1.3 High frequency disturbance level<br> 4.1.4 Specific requirements for interface between <br> separate protection equipment and teleprotection <br> equipment<br>4.2 Specific power supply requirements<br> 4.2.1 Power supply variations<br> 4.2.2 Interruptions<br> 4.2.3 Reflected noise<br> 4.2.4 Reverse polarity<br>4.3 Operational requirements<br> 4.3.1 Overall protection requirements<br> 4.3.2 Monitoring and alarms<br>SECTION 5: METHODS FOR PERFORMANCE TESTING<br>5.1 General equipment interface tests<br> 5.1.1 Insulation tests<br> 5.1.2 Impulse withstand test<br> 5.1.3 High frequency disturbance test<br>5.2 Specific power supply tests<br> 5.2.1 Power supply variations<br> 5.2.2 Interruptions<br> 5.2.3 Reflected noise<br> 5.2.4 Reverse polarity<br>5.3 Teleprotection system performance tests<br> 5.3.1 General<br> 5.3.2 Procedure<br> 5.3.3 Reference condition<br> 5.3.4 Current control, monitoring and settings<br> 5.3.5 Application of noise to teleprotection channel<br> 5.3.6 Dependability<br> 5.3.7 Security<br>5.4 Checking alarm functions<br>Figures<br>ANNEXES<br>A Types of analogue comparison protection systems and <br> associated teleprotection schemes<br>B The binary symmetric channel (BSC) model<br>C Bibliography
Applies to narrowbank and widebank teleprotection systems used to convey analogue information about the primary quantities such as phase or phase and amplitude.
Document Type | Standard |
Status | Current |
Publisher | International Electrotechnical Committee |
Committee | TC 57 |