IEC 62241 : 1.0
IEC 62241 : 1.0
NUCLEAR POWER PLANTS - MAIN CONTROL ROOM - ALARM FUNCTIONS AND PRESENTATION
International Electrotechnical Committee
NUCLEAR POWER PLANTS - MAIN CONTROL ROOM - ALARM FUNCTIONS AND PRESENTATION
International Electrotechnical Committee
FOREWORD<br>INTRODUCTION<br>1 Scope and object<br>2 Normative references<br>3 Terms and definitions<br>4 Background explanations<br> 4.1 Problems of alarm systems<br> 4.2 Functional design elements<br> 4.3 Other elements<br>5 Basic functional requirements<br> 5.1 Alarm functions<br> 5.2 Alarm signals<br> 5.3 Alarm signal processing<br> 5.4 Alarm display processing<br> 5.5 Alarm control and management<br> 5.6 Alarm presentation and display-control integration<br> 5.7 Human factors<br> 5.8 Evaluation<br>6 Design definition of alarms<br> 6.1 General<br> 6.2 Key alarms<br> 6.3 Alarms needed<br>7 Alarm signal processing<br> 7.1 General<br> 7.2 Alarm signal validation<br> 7.3 Alarm generation and reduction processing<br> 7.4 Event sequence and time delay processing<br> 7.5 First-out processing<br>8 Alarm display processing<br> 8.1 General<br> 8.2 Grouped alarms<br> 8.3 Alarm suppression<br> 8.4 Dark-board presentation<br>9 Alarm control and management<br> 9.1 General<br> 9.2 Audible warning and silence<br> 9.3 Flash and reflash<br> 9.4 Acknowledgement<br> 9.5 Ringback<br> 9.6 Reset<br>10 Alarm presentation and display-control integration<br> 10.1 General<br> 10.2 Alarm fascia and tile<br> 10.3 VDU alarm list display<br> 10.4 Audible annunciation<br>11 Reliability, testing, and maintainability<br> 11.1 Reliability<br> 11.2 Testing<br> 11.3 Maintainability<br>12 Alarm recording<br>13 Alarm response procedures (ARP)<br> 13.1 General<br> 13.2 Contents<br> 13.3 Format<br>Annex A (informative) Problems of alarm system<br>Annex B (informative) Information sources for signals used <br> to generate alarms<br>Annex C (informative) Examples of alarm processing logic and <br> dynamic prioritisation<br>Annex D (informative) Conceptual example of alarm grouping <br> and categorisation<br>Annex E (informative) Material for the need of distinction <br> between alarm and status information<br>Annex F (informative) Example of arrangement of alarm tiles<br>Annex G (informative) Examples of Points to Consider in the<br> Categorisation of Alarms
Specifies the functional requirements for the alarm systems in the main control room of nuclear power plants. It provides definitions of the terms used for alarm functions and also establishes the human factors requirements and the design guidelines for alarm presentation for the main control room of nuclear power plants.
Document Type | Standard |
Status | Current |
Publisher | International Electrotechnical Committee |
Committee | TC 45 |