IEC 61076-3-117 : 1.0

IEC 61076-3-117 : 1.0

CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-117: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 14 RELATED TO IEC 61076-3-106 - PUSH-PULL COUPLING

International Electrotechnical Committee

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$31.20

$78.00

(price reduced by 60 %)

Table of Contents

FOREWORD
1 Scope
2 General data
  2.1 Normative references
  2.2 Terms and definitions
3 Dimensional information
  3.1 Common features
  3.2 General
  3.3 Contact arrangement of all connector types
  3.4 IP65 and IP67 sealing
  3.5 Dimensions, fixed connector
  3.6 Dimensions, free connector
  3.7 Termination and mounting information
      3.7.1 General
      3.7.2 Mounting information for fixed connector
4 Gauges
  4.1 Connectors, IEC 60603-7 interface
5 Characteristics
  5.1 Climatic category
  5.2 Electrical characteristics
      5.2.1 Clearance and creepage distances
      5.2.2 Voltage proof
      5.2.3 Current-carrying capacity
      5.2.4 Mating cycles with power applied
      5.2.5 Initial contact resistance
      5.2.6 Input to output resistance
      5.2.7 Resistance unbalance
      5.2.8 Initial insulation resistance
  5.3 Transmission characteristics
      5.3.1 General
  5.4 Mechanical
      5.4.1 Mechanical operation
      5.4.2 Effectiveness of connector coupling devices
            transversal
      5.4.3 Effectiveness of connector coupling devices
      5.4.4 Engagement and separation forces
6 Test schedule
  6.1 General
  6.2 Test procedures and measuring methods
  6.3 Preconditioning
  6.4 Wiring and mounting of specimens
      6.4.1 Wiring
      6.4.2 Mounting
  6.5 Arrangement for contact resistance test
  6.6 Arrangement for dynamic stress tests (test phase AP2)
  6.7 Basic (minimum) test schedule
  6.8 Full test schedule
      6.8.1 General
      6.8.2 Test group P - Preliminary
      6.8.3 Test group P
      6.8.4 Test group AP
      6.8.5 Test group BP
      6.8.6 Test group CP
      6.8.7 Test group DP - Electrical load and temperature
      6.8.8 Test group EP - Signal integrity

Abstract

Describes rectangular protective housings with push-pull coupling for upgrading existing 8-way shielded and unshielded connectors utilizing the interface described in IEC 60603-7-2, IEC 60603-7-3, IEC 60603-7-4, IEC 60603-7-41, IEC 60603-7-5, IEC 60603-7-51, IEC 60603-7-7 and IEC 60603-7-71 to IP65 and IP67 ratings according to IEC 60529, for use in industrial environments.

General Product Information

Document Type Standard
Status Current
Publisher International Electrotechnical Committee
Committee TC 48
Supersedes
  • IEC PAS 61076-3-117 : 1.0

Contact us