Specials

All specials

AS 2564-1982 (R2013)

AS 2564-1982 (R2013)

Aluminium ores - Determination of aluminium, silicon, iron, titanium and phosphorus contents - Wavelength dispersive X-ray fluorescence spectrometric method

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Table of Contents

1 -  AS 2564-1982 ALUMINIUM ORES - DETERMINATION OF ALUMINIUM, SILICON, IRON, TITANIUM AND PHOSPHORUS CONTENTS - WAVELENGTH DISPE
3 -  PREFACE
3 -  CONTENTS
4 -  1 SCOPE AND APPLICATION.
4 -  1.1 Scope.
4 -  1.2 Application.
4 -  2 REFERENCED DOCUMENTS.
4 -  3 PRINCIPLE.
4 -  4 REAGENTS AND MATERIALS.
4 -  4.1 General.
4 -  4.2 Silicon dioxide (SiO2)
4 -  4.3 Aluminium oxide (Al2O3)
4 -  4.4 Synthetic Calibration Sample.
5 -  4.5 Flux.
6 -  4.6 Desiccant.
6 -  5 APPARATUS.
6 -  5.1 Crucible.
6 -  5.2 Desiccator.
6 -  5.3 Electric Furnace.
6 -  5.4 Gas Burner.
6 -  5.5 Specimen Press.
6 -  5.6 Plunger and Platen.
6 -  5.7 Hotplates.
6 -  5.3 Annealing Plates.
6 -  5.9 Carborundum Stone.
6 -  5.10 X-ray Fluorescence Spectrometer.
6 -  6 SAMPLING AND SAMPLES.
6 -  7 PREPARATION OF SPECIMENS INCLUDING LOSS ON FUSION DETERMINATION.
6 -  7.1 Check Test Sample.
6 -  7.2 Aluminium Ore Sample.
10 -  7.3 Blank (or Background) Samples.
10 -  7.4 Synthetic Calibration Sample.
10 -  8 X-RAY FLUORESCENCE MEASUREMENT OF SPECIMENS.
10 -  8.1 General Instrumental Conditions.
11 -  8.2 Sample Holders.
11 -  8.3 Monitor Specimen.
11 -  8.4 Measurement Sequence.
11 -  9 PRELIMINARY CHECK AND CALCULATIONS
11 -  9.1 Reproducibility of Loss on Fusion.
11 -  9.2 Acceptability of Background.
12 -  9.3 Correction for Instrumental Drift.
12 -  9.4 Comparison of Duplicate Measurements.
12 -  9.5 Correction for Dead Time Losses.
12 -  9.6 Conversion to Apparent Concentration.
12 -  9.7 Acceptability of Specimens.
13 -  10 CALCULATION OF RESULTS
13 -  10.1 Loss on Fusion.
13 -  10.2 Oxide Components.
15 -  11 GENERAL TREATMENT OF RESULTS.
15 -  11.1 Precision.
15 -  11.2 Acceptance of Analytical Values.
16 -  12 TEST REPORT.
17 -  APPENDIX A - PREPARATION OF A MONITOR SPECIMEN
17 -  A1 SCOPE.
17 -  A2 INTRODUCTION.
17 -  A3 PREPARATION OF GLASS FOR MONITOR SPECIMEN.
18 -  A4 PREPARATION OF THE MONITOR SPECIMEN.
19 -  APPENDIX B - COMPUTER PROGRAM FOR DATA MANIPULATION
19 -  B1 SCOPE.
19 -  B2 GENERAL.
19 -  B3 PROGRAM OPTIONS.
19 -  B4 INPUT DATA.
19 -  B5 OUTPUT DATA.

Abstract

Sets out a wavelength dispersive X-ray fluorescence procedure and includes both a computer program for obtaining the results and a statistical evaluation of the method. It is applicable to all normal aluminium ores regardless of mineralogical type.

RECONFIRMATION NOTICE
Technical Committee MN-003 has reviewed the content of this publication and in accordance with Standards Australia procedures for reconfirmation, it has been determined that the publication is still valid and does not require change.
Certain documents referenced in the publication may have been amended since the original date of publication. Users are advised to ensure that they are using the latest versions of such documents as appropriate, unless advised otherwise in this Reconfirmation Notice.
Approved for reconfirmation in accordance with Standards Australia procedures for reconfirmation on 29 August 2013.
The following are represented on Technical Committee MN-003:

Australian Aluminium Council
Minerals Council of Australia
Royal Australian Chemical Institute

Scope

This standard sets out a method for the determination of the contents of aluminium, silicon, iron, titanium, and phosphorus (expressed as the oxides Al2O3, SiO2, Fe2O3, TiO2, and P2O5) in aluminium ores by wavelength dispersive X-ray fluorescence spectrometry. The method has been designed to cope with the high and variable loss on ignition of aluminium ores.
Application
The method is applicable to all normal aluminium ores regardless of mineralogical type.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
ProductNote Reconfirmation Notice 03-10-2013
Committee MN-003
Supersedes
  • DR 81218

Contact us