AS 4202-1994

AS 4202-1994

Insulating covers for electrical purposes

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Table of Contents

1 -  AS 4202:1994 INSULATING COVERS FOR ELECTRICAL PURPOSES
4 -  PREFACE
4 -  CONTENTS
5 -  1 SCOPE
5 -  2 REFERENCED DOCUMENTS
5 -  3 DEFINITION
5 -  3.1 Insulating cover
5 -  4 CLASSIFICATION
6 -  5 COMPOSITION
6 -  6 CONSTRUCTION
6 -  7 DIMENSIONS
6 -  7.1 Thickness
6 -  7.2 Width, length and form
6 -  8 COLOUR
6 -  9 WORKMANSHIP AND FINISH
6 -  10 MARKING
6 -  11 TESTS
6 -  11.1 General
6 -  11.2 Electrical insulation
6 -  11.3 Tear resistance
7 -  11.4 Ultraviolet radiation
7 -  11.5 Tensile stress- strain properties
7 -  11.6 Resistance to puncture
8 -  APPENDIX A - STORAGE AND INSPECTION
8 -  A1 STORAGE
8 -  A2 INSPECTION
9 -  APPENDIX B - ELECTRICAL INSULATION TEST
9 -  B1 SCOPE
9 -  B2 APPARATUS
10 -  B3 CONDITIONING OF TEST SPECIMENS
10 -  B3.1 General
10 -  B3.2 Class I type
10 -  B3.3 Class II type
10 -  B4 PREPARATION OF TEST SPECIMENS
10 -  B4.1 General
10 -  B4.2 Class I type
10 -  B4.3 Class II type
10 -  B5 PROCEDURE
10 -  B5.1 Class I type
10 -  B5.2 Class II type
12 -  APPENDIX C - METHOD FOR TESTING RESISTANCE TO PUNCTURE
12 -  C1 SCOPE
12 -  C2 APPARATUS
12 -  C3 PREPARATIONOFTEST SPECIMENS
12 -  C4 PROCEDURE
12 -  C5 REPORT

Abstract

Specifies constructional and test requirements for two classes of flexible insulating covers for indoor and outdoor use. The covers may be tube type or drape type and are intended to be used to cover live equipment, with a working voltage not exceeding 650 V, to prevent accidental contact by persons working nearby..

Scope

This Standard specifies the requirements for two classes of flexible insulating covers for indoor and outdoor use. The covers are intended to be used to cover live conductors, apparatus, surfaces or pipes, and the like, whose nominal voltage does not exceed 650 V, whether a.c. r.m.s. or d.c., between conductors or between conductors and earth, in order to prevent inadvertent contact by personnel or equipment working in the vicinity.
This Standard does not apply to-
(a) insulating covers rated at voltages greater than 650 V; and
(b) insulating mats (see AS 2978).
NOTE: Attention is drawn to Appendix A which provides storage and inspection guidance.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
Committee EL-004