Verification and use of volumetric apparatus General - Volumetric glassware

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Table of Contents

1 -  AS 2162.1-1996 VERIFICATION AND USE OF VOLUMETRIC APPARATUS - GENERAL - VOLUMETRIC GLASSWARE
4 -  PREFACE
5 -  CONTENTS
6 -  1 SCOPE
6 -  2 REFERENCED DOCUMENTS
6 -  3 DEFINITIONS
6 -  3.1 Accuracy
6 -  3.2 Calibration
6 -  3.3 Capacity
6 -  3.4 Error of measurement
6 -  3.5 Measurand
7 -  3.6 Precision
7 -  3.7 Verification
7 -  4 APPARATUS AND MATERIALS
7 -  4.1 Balance
7 -  4.2 Thermometer
7 -  4.3 Barometer
7 -  4.4 Water
7 -  4.5 Pipette filler
7 -  5 FACTORS AFFECTING ACCURACY
7 -  5.1 General
7 -  5.2 Temperature
8 -  5.3 Cleanness of glass surface
8 -  5.4 Setting of meniscus
10 -  5.5 Time of delivery
11 -  5.6 Leakage from stopcocks
11 -  5.7 Other sources of error
12 -  6 VERIFICATION
12 -  6.1 General
12 -  6.2 Water supply
13 -  6.3 Weighing
13 -  6.4 Practical details
16 -  7 THE USE OF VOLUMETRIC GLASSWARE
16 -  7.1 General requirements
16 -  7.2 One-mark volumetric flasks
17 -  7.3 Burettes
17 -  7.4 Pipettes
19 -  APPENDIX A - CLEANING OF VOLUMETRIC GLASSWARE
19 -  A1 METHODS OF CLEANING AND DECONTAMINATION
19 -  A1.1 General
19 -  A1.2 Further cleaning
19 -  A1.3 Decontamination of glassware for use in trace element determinations
19 -  A2 APPLICATION OF CLEANING SOLUTIONS
19 -  A2.1 Burettes and flasks
19 -  A2.2 Pipettes
20 -  A3 STORAGE
21 -  APPENDIX B - METHOD FOR THE DETERMINATION OF DELIVERY TIME
21 -  B1 SCOPE
21 -  B2 BURETTES
21 -  B3 PIPETTES
22 -  APPENDIX C - LEAKAGE TEST FOR BURETTE STOPCOCKS
22 -  C1 SCOPE
22 -  C2 LUBRICATED STOPCOCKS
22 -  C3 LUBRICANT-FREE STOPCOCKS
23 -  APPENDIX D - STOPCOCK LUBRICANTS
23 -  D1 GENERAL INFORMATION
23 -  D2 METHOD OF APPLICATION
23 -  D3 WARNING
24 -  APPENDIX E - CORRECTION TABLES FOR GLASS VESSELS
24 -  E1 SCOPE
24 -  E2 GENERAL
31 -  APPENDIX F - GOOD LABORATORY PRACTICE USING LABORATORY GLASSWARE
31 -  F1 SCOPE
31 -  F2 TEMPERATURE OF LIQUIDS

Abstract

Specifies procedures for the verification of volumetric glassware, using water or mercury as the working substance, and gives recommended practices for the use of such glassware. Factors affecting accuracy are dealt with in some detail; e.g. temperature in respect of both the vessel and the liquid, the cleanness of glass surfaces, the reading of volumes and, for vessels calibrated to deliver, delivery time. Specific attention is given to the correct use of volumetric flasks, pipettes and burettes. Appendices detail methods for cleaning volumetric glassware, a leakage test for burette stopcocks, recommended stopcock lubricants, correction tables for use in calibration, and a list of reference literature, including relevant Australian and British Standards.

Scope

This Standard provides guidance for users wishing to verify or to calibrate their own articles of volumetric glassware by means of water or mercury (when more appropriate) and to enable them to obtain the best accuracy in use.

International Standards and product Standards issued by Standards Australia for individual articles of glassware, include clauses on tolerances and the definition of capacity. These describe in sufficient detail and without ambiguity the method of manipulation to define the capacity. This Standard should be regarded as supplementary to the information contained in glassware product Standards.