Electrical, thermal and loading characteristics of rotating anode X-ray tubes for medical diagnosis

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Table of Contents

1 -  AS/NZS 4394:1996 ELECTRICAL, THERMAL AND LOADING CHARACTERISTICS OF ROTATING ANODE X-RAY TUBES FOR MEDICAL DIAGNOSIS
4 -  PREFACE
5 -  CONTENTS
6 -  1. Scope and object
6 -  1.1 Scope
6 -  1.2 Object
6 -  2. Introduction
6 -  3. Terminology
6 -  3.1 Degree of requirements
6 -  3.2 Definitions
6 -  4. Electrical characteristics of an X-RAY TUBE
6 -  4.1 X-ray tube voltage
6 -  4.1.1 Definition rm-36-02
6 -  4.1.2 Units
7 -  4.2 Nominal X-ray tube voltage
7 -  4.2.1 Definition rm-36-03
7 -  4.2.2 Units
7 -  4.2.3 Presentation of data
7 -  4.3 Limited X-ray tube voltage
7 -  4.3.1 Definition rm-36-04
7 -  4.4 X-ray tube current
7 -  4.4.1 Definition (rm-36-07; see also 3.2)
7 -  4.4.2 Units
7 -  4.5 Cathode emission characteristic
7 -  4.5.1 Definition rm-36-20
7 -  4.5.2 Presentation of data
8 -  5. LOADING of an X-RAY TUBE
8 -  5.1 Loading
8 -  5.1.1 Definition rm-36-09
8 -  5.2 X-ray tube load
8 -  5.2.1 Definition rm-36-21
8 -  5.2.2 Presentation of data
8 -  5.3 Loading factor
8 -  5.3.1 Definition rm-36-01
8 -  5.4 Loading time
8 -  5.4.1 Definition rm-36-10
8 -  5.4.2 Units
8 -  5.4.3 Determination (see IEC 601-2-7, Sub-clause 50.106.3)
9 -  6. Input power
9 -  6.1 Anode input power
9 -  6.1.1 Definition rm-36-22
9 -  6.1.2 Units
9 -  6.2 Nominal anode input power
9 -  6.2.1 Definition (rm-36-23; see also 3.2)
9 -  6.2.2 Units
9 -  6.2.3 Determination
9 -  6.2.4 Statement of compliance
9 -  6.3 Equivalent anode input power
9 -  6.3.1 Definition rm-36-24
9 -  6.3.2 Units
10 -  6.3.3 Determination
10 -  6.4 X-ray tube assembly input power
10 -  6.4.1 Definition rm-36-25
10 -  6.4.2 Units
10 -  7. Thermal characteristics of an ANODE
10 -  7.1 Anode heat content
10 -  7.1.1 Definition rm-36-26
10 -  7.1.2 Units
10 -  7.2 Maximum anode heat content
10 -  7.2.1 Definition rm-36-27
10 -  7.2.2 Units
10 -  7.2.3 Presentation of data
10 -  7.3 Anode heating curve
10 -  7.3.1 Definition rm-36-28
10 -  7.3.2 Presentation of data
11 -  7.4 Anode cooling curve
11 -  7.4.1 Definition rm-36-29
11 -  7.4.2 Presentation of data
11 -  7.5 Verification
12 -  8. Thermal characteristics of an X-RAY TUBE ASSEMBLY
12 -  8.1 X-ray tube assembly heat content
12 -  8.1.1 Definition rm-36-30
12 -  8.1.2 Units
12 -  8.2 Maximum X-ray tube assembly heat content
12 -  8.2.1 Definition rm-36-31
12 -  8.2.2 Units
12 -  8.2.3 Presentation of data
13 -  8.3 X-ray tube assembly heating curve
13 -  8.3.1 Definition rm-36-32
13 -  8.3.2 Presentation of data
13 -  8.4 X-ray tube assembly cooling curve
13 -  8.4.1 Definition rm-36-33
13 -  8.4.2 Presentation of data
13 -  8.4.3 Verification
13 -  8.5 Maximum continuous heat dissipation
13 -  8.5.1 Definition rm-36-34
13 -  8.5.2 Units
13 -  8.5.3 Verification
14 -  9. RADIOGRAPHIC RATINGS of an X-RAY TUBE
14 -  9.1 Single load rating
14 -  9.1.1 Definition rm-36-37
14 -  9.1.2 Presentation of data
14 -  9.1.3 Determination
14 -  9.1.4 Statement of compliance
14 -  9.2 Serial load rating
14 -  9.2.1 Definition rm-36-38
14 -  9.2.2 Presentation of data
15 -  9.2.3 Verification
15 -  9.3 Decreasing input power rating
15 -  9.3.1 Definition rm-36-39
15 -  9.3.2 Presentation of data
16 -  ANNEX A - TERMINOLOGY
17 -  ANNEX B - GUIDANCE ON TYPE TESTING

Abstract

Defines the most common operating characteristics of rotating anode X-ray tubes, during and after energization, to facilitate comparison between these devices. Identical with and has been reproduced from IEC 613:1989.

Scope

This International Standard applies to ROTATING ANODE X-RAY TUBES and X-RAY TUBE ASSEMBLIES intended for use in medical diagnosis.