AS 4260-1997 (R2018)

AS 4260-1997 (R2018)

High efficiency particulate air (HEPA) filters - Classification, construction and performance

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Table of Contents

1 -  AS 4260-1997 HIGH EFFICIENCY PARTICULATE AIR (HEPA) FILTERS - CLASSIFICATION, CONSTRUCTION AND PERFORMANCE
4 -  PREFACE
5 -  CONTENTS
6 -  SECTION 1 SCOPE AND GENERAL
6 -  1.1 SCOPE
6 -  1.2 REFERENCED DOCUMENTS
7 -  1.3 DEFINITIONS
7 -  1.3.1 Casing
7 -  1.3.2 Cold generated DOP test aerosol (Cold DOP)
7 -  1.3.3 Combustible material
7 -  1.3.4 Equivalent penetration
7 -  1.3.5 Filtration efficiency
7 -  1.3.6 High efficiency particulate air (HEPA) filter
7 -  1.3.7 Initial resistance
7 -  1.3.8 Media
7 -  1.3.9 Media adhesive
7 -  1.3.10 Medium efficiency particulate air (MEPA) filter
8 -  1.3.11 Mounting seal
8 -  1.3.12 Normalization
8 -  1.3.13 Patching
8 -  1.3.14 Penetration
8 -  1.3.15 Rated airflow
8 -  1.3.16 Separator
8 -  1.3.17 Sodium chloride test aerosol
8 -  1.3.18 Splicing
8 -  1.3.19 Test aerosol
8 -  1.3.20 Thermally generated (hot) DOP test aerosol
8 -  1.3.21 Ultra low penetration air (ULPA) filter
8 -  1.4 NEW DESIGNS AND INNOVATIONS
9 -  SECTION 2 CLASSIFICATION
9 -  2.1 TYPE AND CLASS
9 -  2.2 PERFORMANCE GRADES
9 -  2.3 MEDIA CLASSIFICATION
10 -  SECTION 3 CONSTRUCTION
10 -  3.1 MATERIALS AND FINISH OF COMPONENTS
10 -  3.1.1 General
10 -  3.1.2 Casing
10 -  3.1.3 Separators
10 -  3.1.4 Adhesives and sealants
10 -  3.1.5 Mounting seals
10 -  3.2 DIMENSIONS, TOLERANCES AND CAPACITY
10 -  3.2.1 Casing dimensions
11 -  3.2.2 Tolerances
11 -  3.3 PLEAT CONFIGURATION
11 -  3.3.1 General
11 -  3.3.2 Filters with separators
12 -  3.3.3 Self-supporting filters
12 -  3.4 CASING
12 -  3.5 MEDIA PACK
12 -  3.6 SPLICING
12 -  3.7 PATCHING MEDIA
12 -  3.8 MOUNTINGSEALS
13 -  SECTION 4 MARKING AND PACKAGING
13 -  4.1 MARKING OF FILTER
13 -  4.2 PACKAGING
13 -  4.3 MARKING OF PACKAGE
14 -  SECTION 5 PERFORMANCE TESTING
14 -  5.1 FILTRATION EFFICIENCY
14 -  5.2 SCAN TESTING FOR FILTER INTEGRITY
14 -  5.3 STRUCTURAL TESTING OF FILTER PACK
14 -  5.4 FIRE PERFORMANCE
15 -  APPENDIX A - PURCHASING GUIDELINES
15 -  A1 GENERAL
15 -  A2 INFORMATION TO BE SUPPLIED BY THE BUYER
15 -  A3 PUBLISHED DATA
15 -  A4 INSPECTION
15 -  A5 ON-SITE TESTING
16 -  APPENDIX B - HANDLING AND SHIPMENT OF HEPA FILTERS
17 -  APPENDIX C - STRUCTURAL STRENGTH
17 -  C1 GENERAL
17 -  C2 RESISTANCE TO VIBRATION
17 -  C3 PRESSURE DROP RESISTANCE
17 -  C4 STRUCTURAL STRENGTH OF FILTER PACK
18 -  APPENDIX D - RESISTANCE TO VIBRATION TEST
18 -  D1 GENERAL
18 -  D2 PRINCIPLE
18 -  D3 TEST ENVIRONMENT
18 -  D4 TEST SPECIMEN
18 -  D5 APPARATUS
18 -  D6 PROCEDURES
18 -  D7 FAILURE CRITERIA
18 -  D8 TEST REPORT

Abstract

Specifies requirements for the classification, construction and performance testing of fully disposable high efficiency particulate air (HEPA) filters. It includes those filters known as ultra low penetration air (ULPA) filters but excludes medium efficiency particulate air filters (MEPA). An appendix provides requirements for structural strength testing.
RECONFIRMATION NOTICE
Major stakeholders of this publication have reviewed the content of this publication and in accordance with Standards Australia procedures for reconfirmation, it has been determined that the publication is still valid and does not require change.
Certain documents referenced in the publication may have been amended since the original date of publication. Users are advised to ensure that they are using the latest versions of such documents as appropriate, unless advised otherwise in this Reconfirmation Notice.
Approved for reconfirmation in accordance with Standards Australia procedures for reconfirmation on 29 August 2018.

Scope

This Standard specifies requirements for the classification, construction and performance testing of fully disposable high efficiency particulate air (HEPA) filters. It includes those filters known as ultra low penetration air (ULPA) filters but excludes medium efficiency particulate air filters (MEPA).

NOTES:
1 Requirements for air filters for use in general ventilation and airconditioning are given in AS 1324.1 and AS 1324.2. Although MEPA filters are not within the scope of this Standard it is recognized that there are similarities of construction, and relevant parts of this Standard may be applied to MEPA filters by buyer/seller agreement.
2 The filters covered by this Standard achieve very low sub-micrometre particulate levels for the protection of people, products, and processes from potential contamination. Common applications are cleanrooms for control and protection of pharmaceutical and electronic processes, operating theatres, clean workstations, nuclear containment facilities, and biological containment facilities including safety cabinets.
3 Purchasing guidelines are provided in Appendix A. Handling and shipment guidelines are provided in Appendix B.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
ProductNote Reconfirmed 14/09/2018.
This standard has been reconfirmed in Australia in 2018 and remains current in New Zealand. Reconfirmation Notice 14/09/2018
Committee ME-080
Supersedes
  • DR 96246
  • AS 4260.2(Int)-1994
  • AS 4260.1(Int)-1994

Contact us