Specials

All specials

AS/NZS 61558.2.3:2001

AS/NZS 61558.2.3:2001

Safety of power transformers, power supply units and similar devices - Particular requirements for ignition transformers for gas and oil burners (IEC 61558-2-3:1999, IDT)

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Table of Contents

<toc>
<bookmarktable>
<bookmark index=&apos;0&apos;>
<pageno>1</pageno>
<text>AS/NZS 61558.2.3:2001 SAFETY OF POWER TRANSFORMERS, POWER SUPPLY UNITS AND SIMILAR DEVICES - PARTICULAR REQUIREMENTS FOR IGNI</text>
<bookmark index=&apos;1&apos;>
<pageno>4</pageno>
<text>CONTENTS</text>
</bookmark>
<bookmark index=&apos;2&apos;>
<pageno>7</pageno>
<text>PREFACE</text>
</bookmark>
<bookmark index=&apos;3&apos;>
<pageno>9</pageno>
<text>1 Scope</text>
</bookmark>
<bookmark index=&apos;4&apos;>
<pageno>9</pageno>
<text>2 Normative references</text>
</bookmark>
<bookmark index=&apos;5&apos;>
<pageno>10</pageno>
<text>3 Definitions</text>
</bookmark>
<bookmark index=&apos;6&apos;>
<pageno>10</pageno>
<text>4 General requirements</text>
</bookmark>
<bookmark index=&apos;7&apos;>
<pageno>10</pageno>
<text>5 General notes on tests</text>
</bookmark>
<bookmark index=&apos;8&apos;>
<pageno>10</pageno>
<text>6 Rating</text>
</bookmark>
<bookmark index=&apos;9&apos;>
<pageno>11</pageno>
<text>7 Classification</text>
</bookmark>
<bookmark index=&apos;10&apos;>
<pageno>11</pageno>
<text>8 Marking and other information</text>
</bookmark>
<bookmark index=&apos;11&apos;>
<pageno>13</pageno>
<text>9 Protection against accessibility to hazardous live parts</text>
</bookmark>
<bookmark index=&apos;12&apos;>
<pageno>13</pageno>
<text>10 Change of input voltage setting</text>
</bookmark>
<bookmark index=&apos;13&apos;>
<pageno>13</pageno>
<text>11 Output voltage and output current under load</text>
</bookmark>
<bookmark index=&apos;14&apos;>
<pageno>14</pageno>
<text>12 No-load output voltage</text>
</bookmark>
<bookmark index=&apos;15&apos;>
<pageno>14</pageno>
<text>13 Short-circuit voltage</text>
</bookmark>
<bookmark index=&apos;16&apos;>
<pageno>14</pageno>
<text>14 Heating</text>
</bookmark>
<bookmark index=&apos;17&apos;>
<pageno>14</pageno>
<text>15 Short-circuit and overload protection</text>
</bookmark>
<bookmark index=&apos;18&apos;>
<pageno>15</pageno>
<text>16 Mechanical strength</text>
</bookmark>
<bookmark index=&apos;19&apos;>
<pageno>15</pageno>
<text>17 Protection against harmful ingress of dust, solid objects and moisture</text>
</bookmark>
<bookmark index=&apos;20&apos;>
<pageno>15</pageno>
<text>18 Insulation resistance and electric strength</text>
</bookmark>
<bookmark index=&apos;21&apos;>
<pageno>16</pageno>
<text>19 Construction</text>
</bookmark>
<bookmark index=&apos;22&apos;>
<pageno>17</pageno>
<text>20 Components</text>
</bookmark>
<bookmark index=&apos;23&apos;>
<pageno>17</pageno>
<text>21 Internal wiring</text>
</bookmark>
<bookmark index=&apos;24&apos;>
<pageno>17</pageno>
<text>22 Supply connection and other external flexible cables or cords</text>
</bookmark>
<bookmark index=&apos;25&apos;>
<pageno>17</pageno>
<text>23 Terminals for externals conductors</text>
</bookmark>
<bookmark index=&apos;26&apos;>
<pageno>17</pageno>
<text>24 Provision for protective earthing</text>
</bookmark>
<bookmark index=&apos;27&apos;>
<pageno>17</pageno>
<text>25 Screws and connections</text>
</bookmark>
<bookmark index=&apos;28&apos;>
<pageno>17</pageno>
<text>26 Creepage distances, clearances and distances through insulation</text>
</bookmark>
<bookmark index=&apos;29&apos;>
<pageno>18</pageno>
<text>27 Resistance to heat, abnormal heat, fire and tracking</text>
</bookmark>
<bookmark index=&apos;30&apos;>
<pageno>18</pageno>
<text>28 Resistance to rusting</text>
</bookmark>
<bookmark index=&apos;31&apos;>
<pageno>20</pageno>
<text>Annexes</text>
<bookmark index=&apos;32&apos;>
<pageno>20</pageno>
<text>Annex C - Creepage distances and clearances &#150; Material group II</text>
</bookmark>
<bookmark index=&apos;33&apos;>
<pageno>20</pageno>
<text>Annex D - Creepage distances and clearances &#150; Material group I</text>
</bookmark>
</bookmark>
</bookmark>
</bookmarktable>
</toc>

Abstract

Specifies general safety requirements for approval and test purposes for ignition transformers for gas and oil burners. This Standard is an adoption with national modifications and contains the full text of IEC 61558-2-3:1999.

Scope

Replacement:
This International Standard deals with all aspects of safety such as electrical, thermal and mechanical aspects.
This part of IEC 61558 AS/NZS 61558 applies to fixed single-phase air-cooled (natural or forced) associated transformers (incorporated or not) used in the ignition system of gas and oil burners, having a rated supply voltage not exceeding 1 000 V a.c. and a rated frequency not exceeding 500 Hz. The rated output current does not exceed 500 mA a.c.
NOTE 1 Due to the national safety law, in Japan the rated output current does not exceed 50 mA.
The no-load output voltage and the rated no-load output voltage does not exceed 15 000 V a.c.
This standard applies to transformers where double or reinforced insulation between circuits is not required by the installation rules or by the appliance specification.
NOTE 2 The transformers are intended to be associated with equipment to provide voltages different from the supply voltage for the functional requirement of the equipment. The safety insulation may be provided (or completed) by other features of the equipment, such as the body.
This standard is applicable to dry-type transformers. The windings may be encapsulated or non encapsulated.
NOTE 3 For transformers filled with liquid dielectric or pulverised material, such as sand, additional requirements are under consideration.
NOTE 4 Attention is drawn to the fact that
for transformers intended to be used in tropical countries special requirements may be necessary;
for the purposes of this standard, Australia and New Zealand are not considered to be tropical;
in locations where special environmental conditions prevail, particular requirements may be necessary.
This standard also applies to transformers incorporating electronic circuits. This standard does not apply to external circuits and their components intended to be connected to the input and output terminals or socket-outlets of the transformer.
NOTE 5 Electronic ignition transformers are under consideration.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
Committee EL-002
Under Revision
  • DR 10917 CP
Supersedes
  • AS/NZS 3108:1994
  • DR 01941 CP
Superseded By
  • AS/NZS 61558.2.3:2011
  • AS/NZS 61558.2.3:2011 (IEC TEXT)
  • AS/NZS 61558.2.3:2011

Contact us