Specials

All specials

AS/NZS 60598.2.19:2001 (R2013)

AS/NZS 60598.2.19:2001 (R2013)

Luminaires Particular requirements - Air handling luminaires (Safety requirements) (IEC 60598.2.19:1981, MOD)

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Abstract

Specifies safety requirements for air-handling luminaires for use with a ventilation duct or ventilated space, for use with tubular fluorescent lamps on supply voltages up to 1000V. It is reproduced from IEC 60598.2.19:1981 including Amendments 1 and 2 and has been modified for Australian/New Zealand conditions.
RECONFIRMATION NOTICE
Technical Committee EL-041 has reviewed the content of this publication and in accordance with Standards Australia procedures for reconfirmation, it has been determined that the publication is still valid and does not require change.
Certain documents referenced in the publication may have been amended since the original date of publication. Users are advised to ensure that they are using the latest versions of such documents as appropriate, unless advised otherwise in this Reconfirmation Notice.
Approved for reconfirmation in accordance with Standards Australia procedures for reconfirmation on 22 July 2013.
Approved for reconfirmation in New Zealand on behalf of the Standards Council of New Zealand on 29 May 2013.
The following are represented on Technical Committee EL-041:

Australasian Fire and Emergency Service Authorities Council
Australian Industry Group
Certification Interests, New Zealand
Consumers Federation of Australia
Department of Climate Change and Energy Efficiency
Electrical Compliance Testing Association
Electrical Regulatory Authorities Council
Energy Efficiency and Conservation Authority of New Zealand
Fair Trading NSW
IES: The Lighting Society
Institution of Professional Engineers New Zealand
International Accreditation New Zealand
Lighting Council Australia
Lighting Council New Zealand
New Zealand Ministry of Business, Innovation and Employment
New Zealand Lighting Manufacturers and Suppliers

Scope

This section of Part 2 of IEC Publication 60598-1: AS/NZS 60598.1 specifies safety requirements for air-handling luminaires for use with a ventilation duct or ventilated space (plenum), for use with tubular fluorescent lamps on supply voltages not exceeding 1000 V. It is to be read in conjunction with those sections of Part 1 to which reference is made.
Attention is drawn to the fact that this section specifies only the safety aspects of air-handling luminaires; no requirements are specified at present for performance aspects.
Notes:
1 The expression "ventilation" and "ventilated" in this section refers to forced ventilation.
2 No requirements are specified at present in this section for the use of tungsten filament lamps and discharge lamps other than tubular fluorescent lamps.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
ProductNote Reconfirmed 17/10/2013
This standard has been reconfirmed in Australia in 2013 and remains current in New Zealand. Reconfirmation Notice 17/10/2013
Committee EL-041
Supersedes
  • DR 01104 CP

Contact us