Table of Contents
1 -
AS/NZS 61210:2002 CONNECTING DEVICES-FLAT QUICK-CONNECT TERMINATIONS FOR ELECTRICAL COPPER CONDUCTORS-SAFETY REQUIREMENTS (IE
4 -
PREFACE
5 -
CONTENTS
7 -
1 Scope
7 -
2 Normative references
8 -
3 Definitions
8 -
3.1 flat quick-connect termination
8 -
3.2 male tab
8 -
3.3 male test tab
8 -
3.4 female connector
8 -
3.5 detent
9 -
3.6 maximum permissible temperature
9 -
4 General
9 -
5 General requirements for tests
10 -
6 Main characteristics
11 -
7 Marking and information
12 -
8 Constructional requirements
13 -
9 Tests
13 -
9.1 Insertion and withdrawal force
14 -
9.2 Mechanical overload force (for integral tabs or female connectors)
15 -
9.3 Temperature rise
16 -
9.4 Current loading, cyclic
16 -
9.5 Elevated temperature test
17 -
9.6 Tensile strength test for crimped connections
25 -
Annex A - Maximum permissible temperature (maximum service temperature)
26 -
Annex ZZ - Variations to IEC 61210:1993 for application in Australia and New Zealand
26 -
ZZ1 Introduction
26 -
ZZ2 Variations
Abstract
Specifies requirements for flat quick-connect terminations consisting of a male tab size 2.8, 4.8, 6.3 or 9.5 mm and mating female conenctor for use as either an incorporated or an integrated part of an equipment or of a component, or as a separate entity, for connecting electrical copper conductors according to the manufacturer's instructions.
Scope
This Standard applies to flat quick-connect terminations consisting of a male tab of size 2,8, 4,8, 6,3 or 9,5 mm (0,110, 0,187, 0,250, or 0,375 in) and a mating female connector for use as either an incorporated or an integrated part of an equipment or of a component, or as a separate entity, for connecting electrical copper conductors according to the manufacturer's instructions.
Said electrical copper conductors may be flexible or rigid stranded, having a cross-sectional area up to and including 6 mm2 (AWG equal to or greater than 10) or rigid solid having a cross-sectional area up to and including 2,5 mm2 (AWG equal to or greater than 14).
The rated voltage by which electrical energy is utilized, shall not exceed 1 000 V a.c. with a frequency up to and including 1 000 Hz, and 1 500 V d.c. and having the temperature limits applicable to materials used within this standard.
Requirements for insulated male tabs and female connectors are under consideration.
NOTES
1 This standard, where applicable, may be used for conductors made of material other than copper, but not including aluminium.
2 For reasons of safety, it is recommended that flat quick-connect terminations beyond the scope of this standard should not be interchangeable with those of this standard.
3 This standard does not apply to female connectors with positive locking means.
4 The flat quick-connect terminations covered by this standard are not intended to be disconnected by pulling the cable.
This standard does not apply to flat quick-connect terminations for data and signal circuits.
General Product Information
Published
|
|
Document Type
|
Standard |
Status
|
Current |
Publisher
|
Standards Australia
|
ProductNote
|
Pending Revision indicates that as a result of the Aged Standards review process, the document needs updating. If no project proposal, meeting the quality criteria, is received within the 12 month timeframe, the document shall be withdrawn. |
Pages
|
|
ISBN
|
|
Committee
|
EL-004 |
Supersedes
|
|
Revision Of
|
|