Specials

All specials

AS/NZS 4114.1:2003

AS/NZS 4114.1:2003

Spray painting booths, designated spray painting areas and paint mixing rooms Design, construction and testing

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Table of Contents

1 -  AS/NZS 4114.1:2003 SPRAY PAINTING BOOTHS, DESIGNATED SPRAY PAINTING AREAS AND PAINT MIXING ROOMS - DESIGN, CONSTRUCTION...
4 -  PREFACE
5 -  CONTENTS
7 -  SECTION 1 SCOPE AND GENERAL
7 -  1.1 SCOPE
7 -  1.2 APPLICATION
8 -  1.3 REFERENCED DOCUMENTS
8 -  1.4 DEFINITIONS
9 -  1.4.1 Area, hazardous
9 -  1.4.2 Direct-fired heating system
9 -  1.4.3 Indirect-fired heating system
9 -  1.4.4 Operational area
9 -  1.4.5 Paint mixing room
9 -  1.4.6 Spray painting
9 -  1.4.7 Spray painting booth (booth)
9 -  1.4.8 Spray painting area
9 -  1.5 TYPES OF SPRAY PAINTING BOOTHS
10 -  1.6 AIRFLOW SYSTEMS
10 -  1.6.1 Full down draught system
10 -  1.6.2 Semi down draught system
11 -  1.6.3 Cross flow system
11 -  1.6.4 On floor down draught systems
11 -  1.7 CLASSIFICATION OF HAZARDOUS AREAS
11 -  1.7.1 Diagram
12 -  1.7.2 Open-fronted booths
12 -  1.7.3 Enclosed type batch booths
12 -  1.7.4 Tunnel or production booths
12 -  1.7.5 Drying and baking rooms
13 -  SECTION 2 DESIGN AND CONSTRUCTION
13 -  2.1 GENERAL
13 -  2.2 MATERIALS
13 -  2.3 INTERIOR SURFACES
13 -  2.4 EXPANSION
13 -  2.5 DOORS
13 -  2.6 ENTRY/EXIT OF TUNNEL OR PRODUCTION BOOTHS
13 -  2.7 GUARDING OF MOVING PARTS
14 -  2.8 SHELVES
14 -  2.9 EQUIPOTENTIAL BONDING
14 -  2.10 DUCTS
16 -  SECTION 3 SPECIFIC REQUIREMENTS
16 -  3.1 GENERAL
16 -  3.2 OPERATION
16 -  3.3 BOOTH CONSTRUCTION
16 -  3.3.1 Materials
16 -  3.3.2 Supporting structures
16 -  3.3.3 Glazing
16 -  3.3.4 Combustible materials
16 -  3.3.5 Emergency exits
17 -  3.4 ELECTRICAL APPARATUS
17 -  3.4.1 General
17 -  3.4.2 Apparatus for use in the hazardous area
17 -  3.4.3 Luminaires
17 -  3.4.4 Other electrical apparatus and ignition sources
17 -  3.4.5 Infrared heating (IR)
19 -  SECTION 4 VENTILATION OF SPRAY PAINTING BOOTHS
19 -  4.1 GENERAL
19 -  4.2 AIRFLOW
19 -  4.2.1 General
19 -  4.2.2 Ventilation design
22 -  4.3 CONTROL SYSTEMS
22 -  4.3.1 Duration of ventilation system
22 -  4.4 EXHAUST AIR
22 -  4.4.1 Location of exhaust air outlets
22 -  4.4.2 Exhaust ventilation
22 -  4.4.3 Exhaust air cleaning and discharge
23 -  4.4.4 Filters
24 -  SECTION 5 SPRAY PAINTING BOOTH OPERATION
24 -  5.1 GENERAL
24 -  5.2 CYCLE
24 -  5.3 HEATING SYSTEM
24 -  5.3.1 Permitted types
25 -  5.3.2 System requirements
26 -  5.3.3 Heating controls
27 -  SECTION 6 MARKINGS
27 -  6.1 GENERAL
27 -  6.2 ADDITIONAL INFORMATION
27 -  6.3 WARNING SIGN
28 -  SECTION 7 VERIFICATION AND TESTS
28 -  7.1 GENERAL
28 -  7.1.1 Purpose
28 -  7.1.2 Compliance
28 -  7.2 VERIFICATION OF DOCUMENTS AND DESIGN
28 -  7.3 RUNNING TEST
28 -  7.4 VENTILATION SYSTEM TEST
28 -  7.5 AIRFLOW TESTING
29 -  APPENDIX A - RELEVANT AUTHORITIES
29 -  A1 SCOPE
29 -  A2 AUTHORITIES IN AUSTRALIA
30 -  A3 AUTHORITIES IN NEW ZEALAND
31 -  APPENDIX B - PAINT MIXING ROOMS
31 -  B1 APPLICATION
31 -  B2 TYPES OF PAINT MIXING ROOMS
32 -  B3 CLASSIFICATION OF HAZARDOUS AREAS WITHIN PAINT MIXING ROOMS
32 -  B4 DESIGN AND CONSTRUCTION
32 -  B4.1 General
32 -  B4.2 Materials
32 -  B4.3 Interior surfaces
32 -  B4.4 Doors
32 -  B4.5 Guarding of moving parts
32 -  B4.6 Shelves
32 -  B4.7 Ducts
33 -  B5 SPECIFIC REQUIREMENTS
33 -  B5.1 General
33 -  B5.2 ACCESS LIMITATIONS
33 -  B5.3 Room construction
33 -  B6 ELECTRICAL APPARATUS
33 -  B6.1 General
33 -  B6.2 Equipotential bonding
33 -  B7 VENTILATION
33 -  B7.1 Exhaust rate
33 -  B7.2 Exhaust air
34 -  B7.3 Operating pressure
34 -  B7.4 Exhaust filters
34 -  B8 MARKING
34 -  B8.1 General
34 -  B8.2 Additional information
34 -  B8.3 Warning signage
34 -  B9 VERIFICATION AND TESTS
34 -  B9.1 General
34 -  B9.2 Verification of documents and design
35 -  B9.3 RUNNING TEST
35 -  B9.4 VENTILATION SYSTEM TEST
36 -  APPENDIX C - SPRAY PAINTING BOOTH SAFETY DESIGN FORM

Abstract

Specifies requirements for the design, construction and testing of spray painting booths, designated spray painting areas and paint mixing rooms in which there may be an explosion hazard due to the presence of flammable volatiles from the paints and finishes used. It is intended to be read in conjunction with AS 2381.1.

Scope

This Standard specifies requirements for the design, construction, and testing of spray painting booths, designated spray painting areas and paint mixing rooms, in which flammable liquids are used. It also covers booths incorporating baking or heating cycles, using either direct or indirect heating systems. For booths using direct fired heating systems, only those using fuels covered in Australian Standards, and in New Zealand, by the New Zealand Standards for gas installations referenced in the New Zealand Gas Regulations, are covered by this Standard.
The requirements contained in this Standard are supplementary to the requirements for electrical apparatus specified in AS/NZS 3000, Wiring Rules and the relevant requirements of the AS/NZS 2381 series.
NOTES:
1 Attention is drawn to other requirements that may be contained in the respective legislation.
2 Part 2 of this Standard details requirements for the installation and maintenance of spray painting booths, designated spray painting areas and paint mixing rooms.
3 Water-based paints contain flammable liquids in the form of organic solvents.
This Standard applies to all types of paints containing flammable liquids including water-based paints, since they also contain organic solvents.
This Standard does not apply to
(a) dry powder type spray booths or operations, the requirements for which are detailed in AS 3754; or
(b) ovens used for the sole purpose of drying or baking.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
Committee EL-014
Supersedes
  • DR 01285
  • AS/NZS 4114.1:1995

Contact us