Specials

All specials

AS 2374.1.2-2003 (R2016)

AS 2374.1.2-2003 (R2016)

Power transformers - Minimum Energy Performance Standard (MEPS) requirements for distribution transformers

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Abstract

Specifies minimum power efficiency levels and high power efficiency levels for oil-immersed and dry-type distribution transformers, with power ratings from 10 kVA to 2500 kVA, intended to be used on 11 kV and 22 kV networks. It is expected that this Standard will be called into legislation by individual States and Territories mandating these requirements under Minimum Energy Performance Standard (MEPS) regulations.
RECONFIRMATION NOTICE
Technical Committee EL-008 has reviewed the content of this publication and in accordance with Standards Australia procedures for reconfirmation, it has been determined that the publication is still valid and does not require change.
Certain documents referenced in the publication may have been amended since the original date of publication. Users are advised to ensure that they are using the latest versions of such documents as appropriate, unless advised otherwise in this Reconfirmation Notice.
Approved for reconfirmation in accordance with Standards Australia procedures for reconfirmation on 25 September 2015.
The following are represented on Technical Committee EL-008:
Australian Chamber of Commerce and Industry
Australian Industry Group
Australian Institute of Petroleum
Electricity Engineers Association (New Zealand)
Energy Efficiency and Conservation Authority of New Zealand
Energy Networks Association
Engineers Australia
Industry Training Body
Rail Industry Safety and Standards Board

Scope

This standard applies to dry-type and oil-immersed type, three-phase and single-phase
power transformers with power ratings from 10 kVA to 2500 kVA and system highest voltage up to 24 kV. This standard does not apply to certain categories of special transformers such as—
(a) transformers other than those on 11 or 22 kv networks;
(b) instrument transformers;
(c) auto transformers;
(d) traction transformers mounted on rolling stock;
(e) starting transformers;
(f) testing transformers;
(g) welding transformers;
(h) three phase transformers with three or more windings per phase;
(i) arc-furnace transformers;
(j) earthing transformers;
(k) rectifier or converter transformers;
(l) uninterruptible power supply (ups) transformers;
(m) transformers with an impedance less than 3% or more than 8%;
(n) voltage regulating transformers;
(o) transformers designed for frequencies other than 50 hertz;
(p) gas-filled dry-type transformers; or
(q) flameproof transformers.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
ProductNote Reconfirmed 27/05/2016.
This standard has been reconfirmed in Australia in 2016 and remains current in New Zealand. Reconfirmation Notice 27/05/2016
Committee EL-008
Supersedes
  • DR 02282 CP

Contact us