AS 1324.2-2003
AS 1324.2-2003
Air filters for use in general ventilation and airconditioning Methods of test
Standards Australia
Air filters for use in general ventilation and airconditioning Methods of test
Standards Australia
<toc>
<bookmarktable>
<bookmark index='0'>
<pageno>1</pageno>
<text>AS 1324.2-2003 AIR FILTERS FOR USE IN GENERAL VENTILATION AND AIRCONDITIONING - METHODS OF TEST</text>
<bookmark index='1'>
<pageno>4</pageno>
<text>PREFACE</text>
</bookmark>
<bookmark index='2'>
<pageno>5</pageno>
<text>CONTENTS</text>
</bookmark>
<bookmark index='3'>
<pageno>7</pageno>
<text>SECTION 1 SCOPE AND GENERAL</text>
<bookmark index='4'>
<pageno>7</pageno>
<text>1.1 SCOPE</text>
</bookmark>
<bookmark index='5'>
<pageno>7</pageno>
<text>1.2 REFERENCED DOCUMENTS</text>
</bookmark>
<bookmark index='6'>
<pageno>7</pageno>
<text>1.3 GENERAL INFORMATION</text>
</bookmark>
<bookmark index='7'>
<pageno>8</pageno>
<text>1.4 DEFINITIONS</text>
</bookmark>
</bookmark>
<bookmark index='8'>
<pageno>9</pageno>
<text>SECTION 2 INITIAL RESISTANCE</text>
<bookmark index='9'>
<pageno>9</pageno>
<text>2.1 SCOPE</text>
</bookmark>
<bookmark index='10'>
<pageno>9</pageno>
<text>2.2 APPLICATION</text>
</bookmark>
<bookmark index='11'>
<pageno>9</pageno>
<text>2.3 PRINCIPLE</text>
</bookmark>
<bookmark index='12'>
<pageno>9</pageno>
<text>2.4 APPARATUS AND MATERIALS</text>
</bookmark>
<bookmark index='13'>
<pageno>9</pageno>
<text>2.5 PROCEDURE</text>
</bookmark>
<bookmark index='14'>
<pageno>9</pageno>
<text>2.6 TEST REPORT</text>
</bookmark>
</bookmark>
<bookmark index='15'>
<pageno>10</pageno>
<text>SECTION 3 MASS STABILIZATION</text>
<bookmark index='16'>
<pageno>10</pageno>
<text>3.1 SCOPE</text>
</bookmark>
<bookmark index='17'>
<pageno>10</pageno>
<text>3.2 APPLICATION</text>
</bookmark>
<bookmark index='18'>
<pageno>10</pageno>
<text>3.3 PRINCIPLE</text>
</bookmark>
<bookmark index='19'>
<pageno>10</pageno>
<text>3.4 APPARATUS AND MATERIALS</text>
</bookmark>
<bookmark index='20'>
<pageno>10</pageno>
<text>3.5 PROCEDURE</text>
</bookmark>
<bookmark index='21'>
<pageno>10</pageno>
<text>3.6 TEST REPORT</text>
</bookmark>
</bookmark>
<bookmark index='22'>
<pageno>11</pageno>
<text>SECTION 4 TEST DUST NO. 1-EFFICIENCY TEST</text>
<bookmark index='23'>
<pageno>11</pageno>
<text>4.1 SCOPE</text>
</bookmark>
<bookmark index='24'>
<pageno>11</pageno>
<text>4.2 APPLICATON</text>
</bookmark>
<bookmark index='25'>
<pageno>11</pageno>
<text>4.3 PRINCIPLE</text>
</bookmark>
<bookmark index='26'>
<pageno>11</pageno>
<text>4.4 COMPOSITION</text>
</bookmark>
<bookmark index='27'>
<pageno>11</pageno>
<text>4.5 NOTATION</text>
</bookmark>
<bookmark index='28'>
<pageno>12</pageno>
<text>4.6 APPARATUS</text>
<bookmark index='29'>
<pageno>12</pageno>
<text>4.6.1 General</text>
</bookmark>
<bookmark index='30'>
<pageno>12</pageno>
<text>4.6.2 Air sample size</text>
</bookmark>
</bookmark>
<bookmark index='31'>
<pageno>12</pageno>
<text>4.7 PROCEDURE</text>
<bookmark index='32'>
<pageno>12</pageno>
<text>4.7.1 Routine test preparation</text>
</bookmark>
<bookmark index='33'>
<pageno>13</pageno>
<text>4.7.2 Zero efficiency test</text>
</bookmark>
<bookmark index='34'>
<pageno>13</pageno>
<text>4.7.3 Test procedure</text>
</bookmark>
</bookmark>
<bookmark index='35'>
<pageno>14</pageno>
<text>4.8 CALCULATIONS</text>
</bookmark>
<bookmark index='36'>
<pageno>16</pageno>
<text>4.9 TEST REPORT</text>
</bookmark>
</bookmark>
<bookmark index='37'>
<pageno>17</pageno>
<text>SECTION 5 TEST DUST NO. 4-GRAVIMETRIC TESTS</text>
<bookmark index='38'>
<pageno>17</pageno>
<text>5.1 SCOPE</text>
</bookmark>
<bookmark index='39'>
<pageno>17</pageno>
<text>5.2 PRINCIPLE</text>
</bookmark>
<bookmark index='40'>
<pageno>17</pageno>
<text>5.3 APPARATUS, MATERIALS AND REAGENTS</text>
</bookmark>
<bookmark index='41'>
<pageno>18</pageno>
<text>5.4 PROCEDURE</text>
</bookmark>
<bookmark index='42'>
<pageno>18</pageno>
<text>5.5 CALCULATIONS</text>
<bookmark index='43'>
<pageno>18</pageno>
<text>5.5.1 Arrestance</text>
</bookmark>
<bookmark index='44'>
<pageno>19</pageno>
<text>5.5.2 Average arrestance</text>
</bookmark>
<bookmark index='45'>
<pageno>19</pageno>
<text>5.5.3 Dust holding capacity</text>
</bookmark>
</bookmark>
<bookmark index='46'>
<pageno>19</pageno>
<text>5.6 TEST REPORT</text>
</bookmark>
</bookmark>
<bookmark index='47'>
<pageno>20</pageno>
<text>SECTION 6 EFFECTIVENESS OF RENEWING MECHANISM</text>
<bookmark index='48'>
<pageno>20</pageno>
<text>6.1 SCOPE</text>
</bookmark>
<bookmark index='49'>
<pageno>20</pageno>
<text>6.2 PRINCIPLE</text>
</bookmark>
<bookmark index='50'>
<pageno>20</pageno>
<text>6.3 APPARATUS AND MATERIALS</text>
</bookmark>
<bookmark index='51'>
<pageno>20</pageno>
<text>6.4 TEST SAMPLE FILTER</text>
</bookmark>
<bookmark index='52'>
<pageno>20</pageno>
<text>6.5 PROCEDURE</text>
</bookmark>
<bookmark index='53'>
<pageno>20</pageno>
<text>6.6 TEST REPORT</text>
</bookmark>
</bookmark>
<bookmark index='54'>
<pageno>21</pageno>
<text>SECTION 7 TEST DUSTS NOS 2 AND 3-SPECIAL TESTS</text>
<bookmark index='55'>
<pageno>21</pageno>
<text>7.1 SCOPE</text>
</bookmark>
<bookmark index='56'>
<pageno>21</pageno>
<text>7.2 APPLICATION</text>
</bookmark>
<bookmark index='57'>
<pageno>21</pageno>
<text>7.3 GRAVIMETRIC TESTS</text>
</bookmark>
<bookmark index='58'>
<pageno>21</pageno>
<text>7.4 EFFECTIVENESS OF RENEWING MECHANISM TEST</text>
</bookmark>
<bookmark index='59'>
<pageno>21</pageno>
<text>7.5 TEST DUST COMPOSITION</text>
</bookmark>
<bookmark index='60'>
<pageno>21</pageno>
<text>7.6 TEST REPORTS</text>
</bookmark>
</bookmark>
<bookmark index='61'>
<pageno>22</pageno>
<text>SECTION 8 TEST REPORTS</text>
<bookmark index='62'>
<pageno>22</pageno>
<text>8.1 REPORTS</text>
</bookmark>
<bookmark index='63'>
<pageno>22</pageno>
<text>8.2 GRAPHS</text>
</bookmark>
<bookmark index='64'>
<pageno>22</pageno>
<text>8.3 PRELIMINARY INFORMATION</text>
</bookmark>
<bookmark index='65'>
<pageno>22</pageno>
<text>8.4 INFORMATION</text>
<bookmark index='66'>
<pageno>22</pageno>
<text>8.4.1 Initial resistance test</text>
</bookmark>
<bookmark index='67'>
<pageno>23</pageno>
<text>8.4.2 Mass stabilization test</text>
</bookmark>
<bookmark index='68'>
<pageno>23</pageno>
<text>8.4.3 Efficiency/arrestance test</text>
</bookmark>
<bookmark index='69'>
<pageno>24</pageno>
<text>8.4.4 Gravimetric tests</text>
</bookmark>
<bookmark index='70'>
<pageno>24</pageno>
<text>8.4.5 Effectiveness of renewing mechanism test</text>
</bookmark>
</bookmark>
<bookmark index='71'>
<pageno>24</pageno>
<text>8.5 DEVIATIONS FROM STANDARD TEST PROCEDURE</text>
</bookmark>
</bookmark>
<bookmark index='72'>
<pageno>26</pageno>
<text>APPENDIX A - GENERAL EQUIPMENT AND TEST REQUIREMENTS</text>
<bookmark index='73'>
<pageno>26</pageno>
<text>A1 CONDITION OF AIR</text>
</bookmark>
<bookmark index='74'>
<pageno>26</pageno>
<text>A2 TEST RIG</text>
<bookmark index='75'>
<pageno>26</pageno>
<text>A2.1 Ductwork</text>
</bookmark>
<bookmark index='76'>
<pageno>26</pageno>
<text>A2.2 Inlet section</text>
</bookmark>
<bookmark index='77'>
<pageno>26</pageno>
<text>A2.3 Filter housing</text>
</bookmark>
<bookmark index='78'>
<pageno>26</pageno>
<text>A2.4 Outlet section</text>
</bookmark>
<bookmark index='79'>
<pageno>27</pageno>
<text>A2.5 Fan</text>
</bookmark>
</bookmark>
<bookmark index='80'>
<pageno>27</pageno>
<text>A3 PRESSURE GAUGE</text>
</bookmark>
<bookmark index='81'>
<pageno>27</pageno>
<text>A4 COMPRESSED AIR SUPPLY</text>
</bookmark>
<bookmark index='82'>
<pageno>27</pageno>
<text>A5 ORIFICE PLATE MANOMETER</text>
</bookmark>
<bookmark index='83'>
<pageno>27</pageno>
<text>A6 FILTER RESISTANCE MANOMETER</text>
</bookmark>
<bookmark index='84'>
<pageno>27</pageno>
<text>A7 WANDER LEAD</text>
</bookmark>
<bookmark index='85'>
<pageno>27</pageno>
<text>A8 ACCESSORY ITEMS</text>
</bookmark>
<bookmark index='86'>
<pageno>27</pageno>
<text>A9 CONNECTIONS</text>
</bookmark>
<bookmark index='87'>
<pageno>27</pageno>
<text>A10 BALANCES</text>
</bookmark>
<bookmark index='88'>
<pageno>27</pageno>
<text>A11 GRAVIMETRIC DUST FEEDER</text>
</bookmark>
<bookmark index='89'>
<pageno>28</pageno>
<text>A12 ITEMS APPLICABLE TO TEST DUST NO.1, EFFICIENCY TEST</text>
<bookmark index='90'>
<pageno>28</pageno>
<text>A12.1 Atomizer</text>
</bookmark>
<bookmark index='91'>
<pageno>28</pageno>
<text>A12.2 Sample tubes</text>
</bookmark>
<bookmark index='92'>
<pageno>28</pageno>
<text>A12.3 Gas meters</text>
</bookmark>
<bookmark index='93'>
<pageno>28</pageno>
<text>A12.4 Photometer</text>
</bookmark>
<bookmark index='94'>
<pageno>29</pageno>
<text>A12.5 Sampling test papers</text>
</bookmark>
</bookmark>
<bookmark index='95'>
<pageno>29</pageno>
<text>A13 MATERIALS</text>
<bookmark index='96'>
<pageno>29</pageno>
<text>A13.1 Test Dust No. 1</text>
</bookmark>
<bookmark index='97'>
<pageno>29</pageno>
<text>A13.2 Test Dust No. 4</text>
</bookmark>
<bookmark index='98'>
<pageno>30</pageno>
<text>A13.3 Test Dusts Nos. 2 and 3</text>
</bookmark>
<bookmark index='99'>
<pageno>30</pageno>
<text>A13.4 Particle size</text>
</bookmark>
</bookmark>
<bookmark index='100'>
<pageno>30</pageno>
<text>A14 COMPRESSRED AIR FLOWMETER</text>
<bookmark index='101'>
<pageno>30</pageno>
<text>A14.1 Type and capacity</text>
</bookmark>
<bookmark index='102'>
<pageno>30</pageno>
<text>A14.2 Regulator valve</text>
</bookmark>
</bookmark>
<bookmark index='103'>
<pageno>30</pageno>
<text>A15 TEST FILTER SAMPLE PREPARATION</text>
</bookmark>
</bookmark>
</bookmark>
</bookmarktable>
</toc>
Provides a method for laboaratory or bench testing of air filters used in general ventilation and airconditioning systems.
This Standard provides test methods for laboratory or bench testing of air filters used in general ventilation and airconditioning systems. It also includes general information on test dusts, test rig and apparatus.
Test methods for filter applications are given in AS 1324.1.
NOTES:
1 Requirements of performance and construction of air filters for use in general ventilation and airconditioning are specified in AS 1324.1.
2 Methods for on-site testing of High Efficiency Particulate Air filters (HEPA filters) are specified in AS 1807 series. Performance, construction and methods of test for HEPA filters are specified in AS 4260.
Document Type | Standard |
Status | Current |
Publisher | Standards Australia |
Committee | ME-080 |
Supersedes |
|