Abstract

Specifies the requirements for the operation of boilers, including unattended, limited attendance and fully attended. It includes the special features within the control, management and supervision systems, associated valves and fittings, housing and installation for those boilers operating in the unattended or limited attendance modes.
RECONFIRMATION NOTICE
Technical Committee ME-001 has reviewed the content of this publication and in accordance with Standards Australia procedures for reconfirmation, it has been determined that the publication is still valid and does not require change.
Certain documents referenced in the publication may have been amended since the original date of publication. Users are advised to ensure that they are using the latest versions of such documents as appropriate, unless advised otherwise in this Reconfirmation Notice.
Approved for reconfirmation in accordance with Standards Australia procedures for reconfirmation on 13 October 2015.
The following are represented on Technical Committee ME-001:
Australasian Corrosion Association
Australasian Institute of Engineer Surveyors
Australian Aluminium Council
Australian Building Codes Board
Australian Chamber of Commerce and Industry
Australian Industry Group
Australian Institute for the Certification of Inspection Personnel
Australian Institute of Energy
Australian Institute of Petroleum
Bureau of Steel Manufacturers of Australia
Department of Justice and Attorney General (QLD)
Electricity Engineers Association (New Zealand)
Energy Networks Association
Engineers Australia
Institution of Professional Engineers New Zealand
Materials Australia
National Association of Testing Authorities Australia
New Zealand Heavy Engineering Research Association
New Zealand Manufacturers and Exporters Association
SafeWork NSW
Welding Technology Institute of Australia
Worksafe Division, Department of Commerce, Western Australia
Worksafe New Zealand
WorkSafe Victoria

Scope

This Standard specifies the requirements for the operation of boilers, including unattended, limited attendance and fully attended. It includes the special features within the control, management and supervision systems, associated valves and fittings, housing and installation for those boilers operating in the unattended or limited attendance modes. It also details the checking, testing and maintenance requirements for each category of attendance.
The details and limits on the type, design criteria, and usage of unattended, limited attendance and attended boilers to which this Standard is intended to apply are as follows:
(a) Boilers for fixed land installations.
(b) Boilers having a design pressure as shown in Table 1.
(c) Boilers having a power output within the capacity specified in Table 1 for the boiler type and category. (See Note 1.)
(d) Boilers complying with the supervision and maintenance requirements specified in Table 1 for the boiler type and category.
(e) Boilers for the generation of steam, or other vapour, for which duty the types of boilers permitted are—
(i) water-tube type electric type or small boiler types (see Table 1) for unattended operation;
(ii) any type of boiler for limited attendance operation (see Table 1); and
(iii) any type of boiler for attended operation (see Table 1).
(f) Boilers for the heating of water or other liquids at a pressure above that of the atmosphere and to a temperature not less than the normal atmospheric boiling temperature of the liquid, for which duty any type of boiler complying with AS 1228 is permitted for unattended operation, provided that for other than water-tube and electric type boilers, steam or vapour is not generated in the boiler and the boiler drum or shell is fully flooded.
(g) Boilers having any of the following sources of energy input:
(i) Gas fuel (mains or other gases).
(ii) Oil fuel with a closed flashpoint greater than 23°C.
(iii) Solid fuels, including solid-fuel-in-suspension.
(iv) Waste heat fluids.
(v) Electric power.
(vi) Solar energy.
NOTES:
1 This Standard may also be applied to boilers outside the limits specified in Items (a) to (g) where equivalent safety and reliability are required by the owner.
2 Except for definitions in Clause 1.3, other clauses in the Standard refer to steam and water only. The Standard may be applied to other fluids with attention by the owner to the owner’s duty of care to the operational personnel and the general public.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
ProductNote Reconfirmed 27/05/2016.
This standard has been reconfirmed in Australia in 2016 and remains current in New Zealand. Reconfirmation Notice 27/05/2016
Committee ME-001
Supersedes
  • AS 3653-1993
  • DR 02328
  • AS 2593-2001

Contact us