AS/NZS 4886:2007

AS/NZS 4886:2007

Domestic solid fuel burning appliance - Pellet heaters - Determination of flue gas emission

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Table of Contents

1 -  AS/NZS 4886:2007 DOMESTIC SOLID FUEL BURNING APPLIANCE-PELLET HEATERS-DETERMINATION OF FLUE GAS EMISSION
4 -  PREFACE
5 -  CONTENTS
7 -  SECTION 1 SCOPE AND GENERAL
7 -  1.1 SCOPE
7 -  1.2 APPLICATION
7 -  1.2.1 General
7 -  1.2.2 Included appliances
7 -  1.2.3 Excluded appliances
7 -  1.3 REFERENCED DOCUMENTS
8 -  1.4 DEFINITIONS
8 -  1.4.1 Appliance particulate emission factor
8 -  1.4.2 Central heating appliance
8 -  1.4.3 Cooking stove appliances
8 -  1.4.4 Particulate emission factor
8 -  1.4.5 Shall
8 -  1.4.6 Should
8 -  1.4.7 Standard temperature
8 -  1.4.8 Standard pressure
8 -  1.5 PRINCIPLE
9 -  SECTION 2 APPARATUS AND REAGENT
9 -  2.1 GENERAL
9 -  2.2 AMBIENT TEMPERATURE MEASUREMENT SYSTEM
9 -  2.3 AMBIENT AIR PRESSURE MEASUREMENT SYSTEM
9 -  2.4 WEIGHT DETERMINATION SYSTEM
9 -  2.5 SAMPLING TRAIN
10 -  2.6 DRAUGHT GAUGE
10 -  2.7 DESICCATORS
10 -  2.8 ACETONE
10 -  2.9 DISHES
10 -  2.10 CARBON DIOXIDE ANALYZER (OPTIONAL)
12 -  SECTION 3 CONFIGURATION OF TEST EQUIPMENT
12 -  3.1 GENERAL
12 -  3.2 DILUTION TUNNEL
12 -  3.2.1 Hood
12 -  3.2.2 Connectors
12 -  3.2.3 Bends
12 -  3.2.4 Sampling section
12 -  3.2.5 Extraction fan
12 -  3.2.6 Component assembly
12 -  3.2.7 Pitot tube location
13 -  3.3 SAMPLING TRAIN
13 -  3.3.1 General
13 -  3.3.2 Probe
13 -  3.3.3 Filter coupling
13 -  3.3.4 Temperature probes
13 -  3.3.5 Dryer coupling
13 -  3.3.6 Exhaust pump
13 -  3.3.7 Joint seals
14 -  SECTION 4 CALIBRATIONS
14 -  4.1 GENERAL
14 -  4.2 DRY GAS METER
14 -  4.3 DILUTION TUNNEL
14 -  4.4 WEIGHING INSTRUMENTS
14 -  4.5 TEMPERATURE MEASUREMENT
14 -  4.6 DIFFERENTIAL PRESSURE MANOMETER AND DRAUGHT GAUGE
14 -  4.7 CARBON DIOXIDE ANALYZER
15 -  SECTION 5 TEST FUEL
16 -  SECTION 6 TEST PROCEDURE
16 -  6.1 GENERAL
16 -  6.2 DILUTION HOOD AND TUNNEL
16 -  6.3 DILUTION TUNNEL
16 -  6.3.1 General
16 -  6.3.2 Flue pipe draft
16 -  6.4 TEST PREPARATION
16 -  6.4.1 Appliance preparation
16 -  6.4.2 Sample collection system
16 -  6.5 TEST FUEL LOAD
16 -  6.6 BURN CYCLES
17 -  6.7 SAMPLING TRAIN OPERATION
17 -  6.8 SAMPLE TREATMENT
17 -  6.9 SAMPLE MEASUREMENT
17 -  6.10 CALCULATIONS
17 -  6.10.1 Sample weight
18 -  6.10.2 Sample flow volume
18 -  6.10.3 Dilution tunnel flow volume
18 -  6.10.4 Volume ratio
18 -  6.10.5 Particulate emission weight
18 -  6.10.6 Particulate emission factor
18 -  6.10.7 Burn-rate emission factors
18 -  6.10.8 Appliance particulate emission factor
19 -  SECTION 7 MAXIMUM ALLOWABLE APPLIANCE PARTICULATE EMISSION FACTOR
19 -  7.1 PELLET BURNING APPLIANCES
19 -  7.2 VALID TESTS
20 -  SECTION 8 TESTING DOCUMENTATION AND TEST REPORTS
20 -  8.1 GENERAL
20 -  8.2 DOCUMENTATION
21 -  8.3 TEST REPORT
21 -  8.4 RETENTION OF RECORDS
21 -  8.5 PUBLISHED RESULTS
22 -  SECTION 9 VARIATION FROM TESTED APPLIANCE
22 -  9.1 GENERAL
22 -  9.2 RETESTING EXEMPTION
23 -  SECTION 10 MARKING
24 -  APPENDIX A - DRY GAS METER CALIBRATION
24 -  A1 SCOPE
24 -  A2 PRINCIPLE
24 -  A3 APPARATUS
24 -  A4 PROCEDURE
25 -  A5 REPORT
26 -  APPENDIX B - DILUTION TUNNEL CALIBRATION
26 -  B1 SCOPE
26 -  B2 PRINCIPLE
26 -  B3 PROCEDURE
26 -  B4 REPORT
27 -  APPENDIX C - CARBON DIOXIDE INSTRUMENT CALIBRATION
27 -  C1 SCOPE
27 -  C2 PRINCIPLE
27 -  C3 APPARATUS
27 -  C4 CALIBRATION PROCEDURE
28 -  C5 CALIBRATION BEFORE EACH USE

Abstract

Specifies a method for determining the rate of particulate emission from batch fed domestic pellet burning appliances.

Scope

This Standard specifies a test method for determining the rate of particulate emission from automatic continuous feed, domestic pellet burning appliances and the associated particulate emission acceptance criteria.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
Committee CS-062
Supersedes
  • DR 06583 CP

Contact us