AS/NZS 4805.2:2007 (R2018)

AS/NZS 4805.2:2007 (R2018)

Accessories for electric cables - Test requirements Impregnated paper-insulated metal-sheathed cables for rated voltages from 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV (excluding gas-pressure and oil-filled cables)

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Table of Contents

1 -  AS/NZS 4805.2:2007 ACCESSORIES FOR ELECTRIC CABLES-TEST REQUIREMENTS - IMPREGNATED PAPER-INSULATED METAL-SHEATHED CABLES...
4 -  PREFACE
5 -  CONTENTS
6 -  SECTION 1 SCOPE AND GENERAL
6 -  1.1 SCOPE
6 -  1.2 REFERENCED DOCUMENTS
7 -  1.3 DEFINITIONS
7 -  1.3.1 Branch joint
7 -  1.3.2 Connector
7 -  1.3.3 Erosion
7 -  1.3.4 Indoor termination
7 -  1.3.5 Outdoor termination
7 -  1.3.6 Straight joint
7 -  1.3.7 Terminal box
7 -  1.3.8 Termination
7 -  1.3.9 Tracking
8 -  1.3.10 Transition joint
8 -  1.4 VOLTAGE DESIGNATIONS AND TEMPERATURE RATING
8 -  1.4.1 Rated voltages
8 -  1.4.2 Rated temperature
9 -  SECTION 2 ASSEMBLY OF ACCESSORIES TO BE TESTED
9 -  2.1 CABLES
9 -  2.2 CONNECTORS
9 -  2.3 ACCESSORIES
9 -  2.4 ASSEMBLY INSTRUCTIONS
9 -  2.5 CONDITION OF ACCESSORIES
9 -  2.6 RECORDING
10 -  SECTION 3 CONDITIONS AND RANGE OF APPROVAL
10 -  3.1 RANGE OF APPROVAL
10 -  3.2 CONDUCTOR MATERIAL
10 -  3.3 FORM OF CONDUCTOR
10 -  3.4 NUMBER OF CORES
10 -  3.5 TYPE OF CABLE
10 -  3.6 RATED VOLTAGE
10 -  3.7 CLEARANCES
11 -  SECTION 4 TESTS
11 -  4.1 CATEGORY OF TESTS
11 -  4.2 TEST METHODS
11 -  4.3 TEST ARRANGMENTS
11 -  4.4 TEST SEQUENCES
11 -  4.5 TEST RESULTS
11 -  4.5.1 General
11 -  4.5.2 Accessory failure
12 -  4.5.3 Cable failure
17 -  APPENDIX A - IDENTIFICATION OF THE TEST CABLE
17 -  A1 PAPER-INSULATED CABLES (see Clause 2.1)
18 -  A2 EXTRUDED INSULATION CABLES (see Clause 2.1)
19 -  APPENDIX B - TEST FOR 'HYDRAULICALLY BLOCKED' CONNECTORS USED IN TRANSITION JOINTS BETWEEN PAPER-IMPREGNATED CABLES AND CABLES WITH EXTRUDED INSULATION
19 -  B1 TEST PROCEDURE
19 -  B2 CRITERIA
21 -  APPENDIX C - HYDRAULIC PRESSURE TEST METHOD FOR CABLE TERMINATIONS
21 -  C1 SCOPE
21 -  C2 APPLICATION AND RANGE OF QUALIFICATION
21 -  C3 PRINCIPLE
21 -  C4 TEST SPECIMENS AND TEST CONFIGURATION
21 -  C5 APPARATUS
22 -  C6 SAMPLE PREPARATION
22 -  C7 PROCEDURE
23 -  C8 CRITERIA OF FAILURE
23 -  C9 TEST REPORT

Abstract

Specifies the requirements for type testing of accessories for impregnated paper-insulated metal-sheathed cables with rated voltages from 1.9/3.3 (3.6) kV up to 19/33 (36) kV.

RECONFIRMATION NOTICE
Technical Committee EL-003 has reviewed the content of this publication and in accordance with Standards Australia procedures for reconfirmation, it has been determined that the publication is still valid and does not require change.
Certain documents referenced in the publication may have been amended since the original date of publication. Users are advised to ensure that they are using the latest versions of such documents as appropriate, unless advised otherwise in this Reconfirmation Notice.
Approved for reconfirmation in accordance with Standards Australia procedures for reconfirmation on 21 March 2018.
Approved for reconfirmation in New Zealand on behalf of the New Zealand Standards Approval Board on 26 June 2018.
The following are represented on Technical Committee EL-003:
Australian Cablemakers Association
Australian Industry Group
Electrical Compliance Testing Association of Australia
Electrical Contractors Association of New Zealand
Electrical Regulatory Authorities Council
Engineers Australia
Institute of Electrical Inspectors
National Electrical and Communications Association
Queensland University of Technology
Worksafe New Zealand

Scope

This Standard specifies the requirements for type testing of accessories for impregnated paper-insulated metal-sheathed cables with rated voltages from 1.9/3.3 (3.6) kV up to 19/33 (36) kV, complying with AS/NZS 1026 or IEC 60055-1.
The accessories covered by this Standard are listed below:
(a) Indoor and outdoor terminations of all designs, including those designed for installations in terminal boxes.
(b) Straight joints and branch joints of all designs, suitable for use underground or in air.
(c) Transition joints connecting paper-insulated cables to cables with extruded insulation.
Accessories for particular cables, such as submarine cables, are not included.
The requirements of the appropriate tests are contained with in Section 4. These type tests shall apply only to new designs of accessories.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
ProductNote Reconfirmed 27/07/2018.
This standard has been reconfirmed in Australia in 2018 and remains current in New Zealand. Reconfirmation Notice 27/07/2018
Committee EL-003
Supersedes
  • AS/NZS 4805.2:2003
  • DR 06569

Contact us