AS/NZS 4805.1:2007

AS/NZS 4805.1:2007

Accessories for electric cables - Test requirements Power cables with extruded insulation for rated voltages from 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Table of Contents

1 -  AS/NZS 4805.1:2007 ACCESSORIES FOR ELECTRIC CABLES-TEST REQUIREMENTS - POWER CABLES WITH EXTRUDED INSULATION FOR RATED...
4 -  PREFACE
6 -  CONTENTS
7 -  SECTION 1 SCOPE AND GENERAL
7 -  1.1 SCOPE
7 -  1.2 REFERENCED DOCUMENTS
8 -  1.3 DEFINITIONS
8 -  1.3.1 Bolted-type separable connector
8 -  1.3.2 Branch joint
8 -  1.3.3 Connector
8 -  1.3.4 Deadbreak connector
8 -  1.3.5 Erosion
8 -  1.3.6 Indoor termination
8 -  1.3.7 Loadbreak connector
8 -  1.3.8 Metallic housing
8 -  1.3.9 Outdoor termination
8 -  1.3.10 Plug-in type separable connector
9 -  1.3.11 Range-taking accessory
9 -  1.3.12 Screened separable connector
9 -  1.3.13 Separable connector
9 -  1.3.14 Shrouded termination
9 -  1.3.15 Straight joint
9 -  1.3.16 Stop-end
9 -  1.3.17 Terminal box
9 -  1.3.18 Termination
9 -  1.3.19 Tracking
9 -  1.3.20 Unscreened separable connector
9 -  1.4 VOLTAGE DESIGNATIONS AND TEMPERATURE RATING
9 -  1.4.1 Rated voltages
9 -  1.4.2 Rated temperature
10 -  SECTION 2 ASSEMBLY OF ACCESSORIES TO BE TESTED
10 -  2.1 CABLES
10 -  2.2 CONNECTORS
10 -  2.3 ACCESSORIES
10 -  2.4 INSTALLATION AND CONNECTIONS
10 -  2.4.1 Cable conductor size
10 -  2.4.2 Assembly instructions
11 -  2.4.3 Condition of accessories
11 -  2.4.4 Connection of separable connectors
11 -  2.4.5 Lug or bushing sizes
11 -  2.4.6 Unscreened separable connectors
11 -  2.4.7 Branch joints
11 -  2.4.8 Recording
11 -  2.4.9 Test arrangements
12 -  SECTION 3 CONDITIONS AND RANGE OF APPROVAL
12 -  3.1 RANGE OF APPROVAL
12 -  3.1.1 Terminations, joints and stop-ends
12 -  3.1.2 Separable connectors
12 -  3.1.3 Range of applicable voltages
12 -  3.2 CONDUCTOR MATERIAL
12 -  3.3 FORM OF CONDUCTOR
12 -  3.4 INSULATION MATERIAL
13 -  3.5 INSULATION SCREEN
13 -  3.6 WATER BLOCKING
13 -  3.7 NUMBER OF CORES
13 -  3.8 CLEARANCES
14 -  SECTION 4 TESTS
14 -  4.1 CATEGORY OF TESTS
14 -  4.2 TEST METHODS
14 -  4.3 TEST ARRANGEMENTS
14 -  4.4 TEST SEQUENCES
15 -  4.5 TEST RESULTS
15 -  4.5.1 General
15 -  4.5.2 Accessory failure
16 -  4.5.3 Cable failure
35 -  APPENDIX A - IDENTIFICATION OF TEST CABLE

Abstract

Specifies the type test requirements on accessories for power cables with extruded insulation and with rated voltages from 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV.

Scope

This Standard specifies the requirements for type testing of accessories for power cables with extruded insulation with rated voltages from 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV, complying with AS/NZS 1429.1 or IEC 60502-2.
The accessories covered by this Standard are listed below:
(a) Indoor and outdoor terminations of all designs, including those designed for installation in terminal boxes.
(b) Straight joints, branch joints and stop-ends of all designs, suitable for use underground or in air.
(c) Screened or unscreened plug-in type or bolted-type separable connectors.
NOTE: Joints connecting cables with extruded insulation to paper-insulated cables are not included. The requirements for these accessories are dealt with in AS/NZS 4805.2.
Accessories for special applications, such as aerial cables, submarine or ship cables or hazardous situations (explosive environments, fire resistant cables or seismic conditions) are not included.
Approval to this Standard is obtained by satisfying the requirements of the appropriate tests as specified in Section 4.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
ProductNote Pending Revision indicates that as a result of the Aged Standards review process, the document needs updating. If no project proposal, meeting the quality criteria, is received within the 12 month timeframe, the document shall be withdrawn.
Committee EL-003