AS/NZS 4284:2008

AS/NZS 4284:2008

Testing of building facades

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Table of Contents

<toc>
<bookmarktable>
<bookmark index='0'>
<pageno>1</pageno>
<text>AS/NZS 4284:2008 TESTING OF BUILDING FACADES</text>
<bookmark index='1'>
<pageno>4</pageno>
<text>PREFACE</text>
</bookmark>
<bookmark index='2'>
<pageno>6</pageno>
<text>CONTENTS</text>
</bookmark>
<bookmark index='3'>
<pageno>7</pageno>
<text>1 SCOPE</text>
</bookmark>
<bookmark index='4'>
<pageno>7</pageno>
<text>2 REFERENCED DOCUMENTS</text>
</bookmark>
<bookmark index='5'>
<pageno>7</pageno>
<text>3 DEFINITIONS</text>
<bookmark index='6'>
<pageno>7</pageno>
<text>3.1 BMU</text>
</bookmark>
<bookmark index='7'>
<pageno>7</pageno>
<text>3.2 Framing members</text>
</bookmark>
<bookmark index='8'>
<pageno>7</pageno>
<text>3.3 Specifier</text>
</bookmark>
<bookmark index='9'>
<pageno>7</pageno>
<text>3.4 Test facility</text>
</bookmark>
<bookmark index='10'>
<pageno>8</pageno>
<text>3.5 Uncontrolled water</text>
</bookmark>
</bookmark>
<bookmark index='11'>
<pageno>8</pageno>
<text>4 NOTATION</text>
</bookmark>
<bookmark index='12'>
<pageno>8</pageno>
<text>5 PRINCIPLE</text>
</bookmark>
<bookmark index='13'>
<pageno>8</pageno>
<text>6 APPARATUS</text>
</bookmark>
<bookmark index='14'>
<pageno>9</pageno>
<text>7 SAMPLE PREPARATION</text>
<bookmark index='15'>
<pageno>9</pageno>
<text>7.1 Test sample</text>
</bookmark>
<bookmark index='16'>
<pageno>9</pageno>
<text>7.2 Drawings</text>
</bookmark>
</bookmark>
<bookmark index='17'>
<pageno>10</pageno>
<text>8 PROCEDURE</text>
<bookmark index='18'>
<pageno>10</pageno>
<text>8.1 Test sequence</text>
<bookmark index='19'>
<pageno>10</pageno>
<text>8.1.1 General</text>
</bookmark>
<bookmark index='20'>
<pageno>10</pageno>
<text>8.1.2 Variation of test sequence or retesting</text>
</bookmark>
</bookmark>
<bookmark index='21'>
<pageno>10</pageno>
<text>8.2 Preliminary tests</text>
<bookmark index='22'>
<pageno>10</pageno>
<text>8.2.1 General</text>
</bookmark>
<bookmark index='23'>
<pageno>10</pageno>
<text>8.2.2 Static pressure</text>
</bookmark>
<bookmark index='24'>
<pageno>10</pageno>
<text>8.2.3 Water</text>
</bookmark>
</bookmark>
<bookmark index='25'>
<pageno>10</pageno>
<text>8.3 Structural test at serviceability limit state</text>
<bookmark index='26'>
<pageno>10</pageno>
<text>8.3.1 Structural-test pressures</text>
</bookmark>
<bookmark index='27'>
<pageno>11</pageno>
<text>8.3.2 Location of the displacement transducers</text>
</bookmark>
<bookmark index='28'>
<pageno>11</pageno>
<text>8.3.3 Pressure loading sequence</text>
</bookmark>
<bookmark index='29'>
<pageno>12</pageno>
<text>8.3.4 Displacement measurement of spandrel panels</text>
</bookmark>
<bookmark index='30'>
<pageno>13</pageno>
<text>8.3.5 Calculation of deflection/span ratio</text>
</bookmark>
<bookmark index='31'>
<pageno>13</pageno>
<text>8.3.6 Calculation of successive member displacement</text>
</bookmark>
<bookmark index='32'>
<pageno>13</pageno>
<text>8.3.7 Calculation of maximum displacement</text>
</bookmark>
</bookmark>
<bookmark index='33'>
<pageno>13</pageno>
<text>8.4 Air infiltration test</text>
<bookmark index='34'>
<pageno>13</pageno>
<text>8.4.1 Test pressure</text>
</bookmark>
<bookmark index='35'>
<pageno>14</pageno>
<text>8.4.2 Procedure</text>
</bookmark>
</bookmark>
<bookmark index='36'>
<pageno>14</pageno>
<text>8.5 Water penetration test by static pressure</text>
<bookmark index='37'>
<pageno>14</pageno>
<text>8.5.1 Test pressure</text>
</bookmark>
<bookmark index='38'>
<pageno>14</pageno>
<text>8.5.2 Procedure</text>
</bookmark>
</bookmark>
<bookmark index='39'>
<pageno>14</pageno>
<text>8.6 Water penetration test by cyclic pressure</text>
<bookmark index='40'>
<pageno>14</pageno>
<text>8.6.1 Test pressure</text>
</bookmark>
<bookmark index='41'>
<pageno>15</pageno>
<text>8.6.2 Procedure</text>
</bookmark>
</bookmark>
<bookmark index='42'>
<pageno>15</pageno>
<text>8.7 BMU restraint test</text>
<bookmark index='43'>
<pageno>15</pageno>
<text>8.7.1 Test load</text>
</bookmark>
<bookmark index='44'>
<pageno>15</pageno>
<text>8.7.2 Procedure</text>
</bookmark>
</bookmark>
<bookmark index='45'>
<pageno>15</pageno>
<text>8.8 Structural test at ultimate limit state</text>
<bookmark index='46'>
<pageno>15</pageno>
<text>8.8.1 Test pressures</text>
</bookmark>
<bookmark index='47'>
<pageno>16</pageno>
<text>8.8.2 Procedure</text>
</bookmark>
<bookmark index='48'>
<pageno>16</pageno>
<text>8.8.3 Spandrel panel</text>
</bookmark>
</bookmark>
<bookmark index='49'>
<pageno>16</pageno>
<text>8.9 Seismic test</text>
<bookmark index='50'>
<pageno>16</pageno>
<text>8.9.1 Test displacement</text>
</bookmark>
<bookmark index='51'>
<pageno>16</pageno>
<text>8.9.2 Procedure</text>
</bookmark>
</bookmark>
<bookmark index='52'>
<pageno>16</pageno>
<text>8.10 Seal degradation test</text>
</bookmark>
</bookmark>
<bookmark index='53'>
<pageno>17</pageno>
<text>9 PERFORMANCE REQUIREMENTS</text>
<bookmark index='54'>
<pageno>17</pageno>
<text>9.1 General</text>
</bookmark>
<bookmark index='55'>
<pageno>17</pageno>
<text>9.2 Structural test at serviceability limit state</text>
<bookmark index='56'>
<pageno>17</pageno>
<text>9.2.1 Deflection/span ratios</text>
</bookmark>
<bookmark index='57'>
<pageno>17</pageno>
<text>9.2.2 Successive member displacement</text>
</bookmark>
<bookmark index='58'>
<pageno>17</pageno>
<text>9.2.3 Maximum displacement</text>
</bookmark>
</bookmark>
<bookmark index='59'>
<pageno>17</pageno>
<text>9.3 Air infiltration test</text>
</bookmark>
<bookmark index='60'>
<pageno>17</pageno>
<text>9.4 Water penetration test</text>
</bookmark>
<bookmark index='61'>
<pageno>17</pageno>
<text>9.5 Seismic test at serviceability limit state displacement</text>
</bookmark>
<bookmark index='62'>
<pageno>17</pageno>
<text>9.6 BMU restraint test</text>
</bookmark>
<bookmark index='63'>
<pageno>18</pageno>
<text>9.7 Structural test at ultimate limit state</text>
</bookmark>
<bookmark index='64'>
<pageno>18</pageno>
<text>9.8 Seismic test at ultimate limit state displacement</text>
</bookmark>
<bookmark index='65'>
<pageno>18</pageno>
<text>9.9 Seal degradation test</text>
</bookmark>
</bookmark>
<bookmark index='66'>
<pageno>18</pageno>
<text>10 TEST REPORT</text>
<bookmark index='67'>
<pageno>18</pageno>
<text>10.1 Preliminary test report</text>
</bookmark>
<bookmark index='68'>
<pageno>18</pageno>
<text>10.2 Official test report</text>
</bookmark>
</bookmark>
<bookmark index='69'>
<pageno>20</pageno>
<text>APPENDIX A - INFORMATION TO BE SUPPLIED BY SPECIFIER</text>
</bookmark>
<bookmark index='70'>
<pageno>23</pageno>
<text>APPENDIX B - SAMPLE PREPARATION</text>
<bookmark index='71'>
<pageno>23</pageno>
<text>B1 INTRODUCTION</text>
</bookmark>
<bookmark index='72'>
<pageno>23</pageno>
<text>B2 TEST SAMPLE</text>
</bookmark>
<bookmark index='73'>
<pageno>25</pageno>
<text>B3 REQUIREMENTS</text>
</bookmark>
<bookmark index='74'>
<pageno>26</pageno>
<text>B4 INCLINED GLAZING</text>
</bookmark>
</bookmark>
<bookmark index='75'>
<pageno>27</pageno>
<text>APPENDIX C - STRENGTH TEST AT ULTIMATE LIMIT STATE LOADING</text>
</bookmark>
<bookmark index='76'>
<pageno>32</pageno>
<text>APPENDIX D - AIR INFILTRATION TESTING</text>
</bookmark>
<bookmark index='77'>
<pageno>34</pageno>
<text>APPENDIX E - WATER PENETRATION TESTING</text>
</bookmark>
<bookmark index='78'>
<pageno>36</pageno>
<text>APPENDIX F - SEISMIC TESTING</text>
</bookmark>
</bookmark>
</bookmarktable>
</toc>

Abstract

Sets out methods of testing building facades for environmental loading including water penetration and air infiltration as well as structural tests. Optional tests include seismic testing, seal degradation and building maintenance unit (BMU) restraint.

Scope

This Standard sets out a method for determining the performance of a representative building facade under simulated conditions of loading. This Standard may be applied to all types of facades including low- and high-rise, commercial, industrial and residential buildings. Tests include displacement of the facade or prototype, water penetration and structural integrity at ultimate limit state as well as optional tests, including BMU restraint, seismic loading and seal degradation. This test method is applicable to prototype testing in a test facility and on-site testing.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
Committee BD-080
Supersedes
  • AS/NZS 4284:1995
  • DR 07156