AS/NZS 4965.1:2008
AS/NZS 4965.1:2008
Performance of close control airconditioners Testing for rating
Standards Australia
Performance of close control airconditioners Testing for rating
Standards Australia
<toc>
<bookmarktable>
<bookmark index='0'>
<pageno>1</pageno>
<text>AS/NZS 4965.1:2008 PERFORMANCE OF CLOSE CONTROL AIRCONDITIONERS - TESTING FOR RATING</text>
<bookmark index='1'>
<pageno>4</pageno>
<text>PREFACE</text>
</bookmark>
<bookmark index='2'>
<pageno>5</pageno>
<text>CONTENTS</text>
</bookmark>
<bookmark index='3'>
<pageno>6</pageno>
<text>1 SCOPE</text>
</bookmark>
<bookmark index='4'>
<pageno>6</pageno>
<text>2 APPLICATION</text>
</bookmark>
<bookmark index='5'>
<pageno>6</pageno>
<text>3 REFERENCED DOCUMENTS</text>
</bookmark>
<bookmark index='6'>
<pageno>6</pageno>
<text>4 DEFINITIONS</text>
<bookmark index='7'>
<pageno>7</pageno>
<text>4.1 Close control airconditioner</text>
</bookmark>
<bookmark index='8'>
<pageno>7</pageno>
<text>4.2 Cooling energy efficiency ratio (EER)</text>
</bookmark>
<bookmark index='9'>
<pageno>7</pageno>
<text>4.3 Effective power input (PE)</text>
</bookmark>
<bookmark index='10'>
<pageno>7</pageno>
<text>4.4 Full load operation</text>
</bookmark>
<bookmark index='11'>
<pageno>7</pageno>
<text>4.5 Gross sensible cooling capacity</text>
</bookmark>
<bookmark index='12'>
<pageno>7</pageno>
<text>4.6 Gross total cooling capacity</text>
</bookmark>
<bookmark index='13'>
<pageno>7</pageno>
<text>4.7 Indoor discharge airflow</text>
</bookmark>
<bookmark index='14'>
<pageno>7</pageno>
<text>4.8 Indoor intake airflow</text>
</bookmark>
<bookmark index='15'>
<pageno>7</pageno>
<text>4.9 Latent capacity-Room dehumidifying capacity</text>
</bookmark>
<bookmark index='16'>
<pageno>7</pageno>
<text>4.10 Net sensible cooling capacity</text>
</bookmark>
<bookmark index='17'>
<pageno>7</pageno>
<text>4.11 Net total cooling capacity</text>
</bookmark>
<bookmark index='18'>
<pageno>7</pageno>
<text>4.12 Outdoor discharge airflow</text>
</bookmark>
<bookmark index='19'>
<pageno>7</pageno>
<text>4.13 Outdoor intake airflow</text>
</bookmark>
<bookmark index='20'>
<pageno>7</pageno>
<text>4.14 Rated frequency(ies)</text>
</bookmark>
<bookmark index='21'>
<pageno>8</pageno>
<text>4.15 Rated voltage(s)</text>
</bookmark>
<bookmark index='22'>
<pageno>8</pageno>
<text>4.16 Sensible energy efficiency ratio (EERS)</text>
</bookmark>
<bookmark index='23'>
<pageno>8</pageno>
<text>4.17 Sensible heat ratio</text>
</bookmark>
<bookmark index='24'>
<pageno>8</pageno>
<text>4.18 Shall</text>
</bookmark>
<bookmark index='25'>
<pageno>8</pageno>
<text>4.19 Should</text>
</bookmark>
<bookmark index='26'>
<pageno>8</pageno>
<text>4.20 Standard air</text>
</bookmark>
</bookmark>
<bookmark index='27'>
<pageno>8</pageno>
<text>5 COOLING TESTS</text>
<bookmark index='28'>
<pageno>8</pageno>
<text>5.1 Cooling capacity ratings</text>
<bookmark index='29'>
<pageno>8</pageno>
<text>5.1.1 General conditions</text>
</bookmark>
<bookmark index='30'>
<pageno>8</pageno>
<text>5.1.2 Temperature conditions</text>
</bookmark>
<bookmark index='31'>
<pageno>8</pageno>
<text>5.1.3 Airflow conditions</text>
</bookmark>
<bookmark index='32'>
<pageno>9</pageno>
<text>5.1.4 Test conditions</text>
</bookmark>
</bookmark>
</bookmark>
<bookmark index='33'>
<pageno>9</pageno>
<text>6 TEST METHODS AND UNCERTAINTY OF MEASUREMENT</text>
<bookmark index='34'>
<pageno>9</pageno>
<text>6.1 Test methods</text>
</bookmark>
<bookmark index='35'>
<pageno>10</pageno>
<text>6.2 Uncertainty of measurement</text>
</bookmark>
<bookmark index='36'>
<pageno>10</pageno>
<text>6.3 Variations in individual readings</text>
</bookmark>
<bookmark index='37'>
<pageno>10</pageno>
<text>6.4 Test tolerances</text>
</bookmark>
<bookmark index='38'>
<pageno>11</pageno>
<text>6.5 Standby power and crankcase heaters</text>
<bookmark index='39'>
<pageno>11</pageno>
<text>6.5.1 General</text>
</bookmark>
<bookmark index='40'>
<pageno>11</pageno>
<text>6.5.2 Off mode</text>
</bookmark>
<bookmark index='41'>
<pageno>12</pageno>
<text>6.5.3 Passive standby mode</text>
</bookmark>
<bookmark index='42'>
<pageno>12</pageno>
<text>6.5.4 Delay start mode</text>
</bookmark>
<bookmark index='43'>
<pageno>12</pageno>
<text>6.5.5 Crankcase heaters</text>
</bookmark>
</bookmark>
<bookmark index='44'>
<pageno>12</pageno>
<text>6.6 Testing airconditioners with variable output compressors</text>
</bookmark>
</bookmark>
<bookmark index='45'>
<pageno>13</pageno>
<text>7 TEST RESULTS</text>
<bookmark index='46'>
<pageno>13</pageno>
<text>7.1 Capacity calculations</text>
<bookmark index='47'>
<pageno>13</pageno>
<text>7.1.1 General</text>
</bookmark>
<bookmark index='48'>
<pageno>13</pageno>
<text>7.1.2 Adjustments</text>
</bookmark>
</bookmark>
<bookmark index='49'>
<pageno>13</pageno>
<text>7.2 Data to be recorded</text>
</bookmark>
<bookmark index='50'>
<pageno>14</pageno>
<text>7.3 Test report</text>
<bookmark index='51'>
<pageno>14</pageno>
<text>7.3.1 General information</text>
</bookmark>
<bookmark index='52'>
<pageno>14</pageno>
<text>7.3.2 Additional information</text>
</bookmark>
<bookmark index='53'>
<pageno>14</pageno>
<text>7.3.3 Rating test results</text>
</bookmark>
</bookmark>
</bookmark>
<bookmark index='54'>
<pageno>16</pageno>
<text>8 PUBLICATION OF RATINGS</text>
<bookmark index='55'>
<pageno>16</pageno>
<text>8.1 Standard ratings</text>
</bookmark>
<bookmark index='56'>
<pageno>16</pageno>
<text>8.2 Other ratings</text>
</bookmark>
</bookmark>
<bookmark index='57'>
<pageno>17</pageno>
<text>APPENDIX A - TEST PROCEDURES</text>
<bookmark index='58'>
<pageno>17</pageno>
<text>A1 GENERAL TEST ROOM REQUIREMENTS</text>
</bookmark>
<bookmark index='59'>
<pageno>17</pageno>
<text>A2 EQUIPMENT INSTALLATION</text>
</bookmark>
<bookmark index='60'>
<pageno>17</pageno>
<text>A3 ELECTRICAL SUPPLY REQUIREMENTS</text>
</bookmark>
</bookmark>
<bookmark index='61'>
<pageno>18</pageno>
<text>APPENDIX B - CALORIMETER TEST METHOD</text>
<bookmark index='62'>
<pageno>18</pageno>
<text>B1 GENERAL</text>
</bookmark>
<bookmark index='63'>
<pageno>23</pageno>
<text>B2 CALIBRATED ROOM-TYPE CALORIMETER</text>
</bookmark>
<bookmark index='64'>
<pageno>24</pageno>
<text>B3 BALANCED AMBIENT ROOM-TYPE CALORIMETER</text>
</bookmark>
<bookmark index='65'>
<pageno>25</pageno>
<text>B4 CALORIMETER AND AUXILIARY EQUIPMENT FOR WATER-COOLED CONDENSER TESTS</text>
</bookmark>
</bookmark>
<bookmark index='66'>
<pageno>26</pageno>
<text>APPENDIX C - HEATING AND COOLING CAPACITY CALCULATIONS</text>
<bookmark index='67'>
<pageno>26</pageno>
<text>C1 COOLING CAPACITY CALCULATIONS (CALORIMETER METHOD)</text>
</bookmark>
<bookmark index='68'>
<pageno>28</pageno>
<text>C2 COOLING CAPACITY CALCULATIONS (AIR-ENTHALPY METHOD)</text>
</bookmark>
</bookmark>
<bookmark index='69'>
<pageno>30</pageno>
<text>APPENDIX D - AIRFLOW MEASUREMENT</text>
<bookmark index='70'>
<pageno>30</pageno>
<text>D1 AIRFLOW DETERMINATION</text>
</bookmark>
<bookmark index='71'>
<pageno>30</pageno>
<text>D2 NOZZLES</text>
</bookmark>
<bookmark index='72'>
<pageno>31</pageno>
<text>D3 APPARATUS FOR ROOM DISCHARGE AIRFLOW MEASUREMENTS</text>
</bookmark>
<bookmark index='73'>
<pageno>32</pageno>
<text>D4 INDOOR-SIDE DISCHARGE AIRFLOW MEASUREMENT</text>
</bookmark>
<bookmark index='74'>
<pageno>33</pageno>
<text>D5 VENTILATION, EXHAUST AND LEAKAGE AIRFLOW MEASUREMENTS</text>
</bookmark>
<bookmark index='75'>
<pageno>33</pageno>
<text>D6 TEST APPARATUS CALIBRATION (AIR-ENTHALPY METHOD)</text>
</bookmark>
</bookmark>
<bookmark index='76'>
<pageno>34</pageno>
<text>APPENDIX E - REFRIGERANT ENTHALPY TEST METHOD</text>
<bookmark index='77'>
<pageno>34</pageno>
<text>E1 GENERAL DESCRIPTION</text>
</bookmark>
<bookmark index='78'>
<pageno>34</pageno>
<text>E2 REFRIGERANT FLOW METHOD</text>
</bookmark>
<bookmark index='79'>
<pageno>34</pageno>
<text>E3 REFRIGERANT TEMPERATURE AND PRESSURE MEASUREMENTS</text>
</bookmark>
<bookmark index='80'>
<pageno>35</pageno>
<text>E4 CALCULATION COOLING CAPACITIES</text>
</bookmark>
</bookmark>
<bookmark index='81'>
<pageno>36</pageno>
<text>APPENDIX F - LIST OF SYMBOLS</text>
</bookmark>
</bookmark>
</bookmarktable>
</toc>
Specifies the conditions on which the capacity and energy consumption of factory-made close control airconditioners are based and the test methods to be applied for determining the capacity and efficiency ratings.
This Standard specifies the conditions on which the capacity and energy consumption of factory-made close control airconditioners are based and the test methods to be applied to determine the capacity and efficiency ratings. This Standard covers equipment utilizing a single or multiple refrigerated direct expansion (DX) system designed to control and monitor temperature and humidity and may include supplementary conditioning equipment.
Appendix A establishes testing procedures. Appendix B describes the test facilities required for the calorimeter method. Appendix C provides formulae for calculating heating and cooling capacities. Appendix D describes methods for measuring airflow. Appendix E describes the refrigerant enthalpy test method. Appendix F lists the symbols used in this Standard.
This Standard does not cover the determination of seasonal efficiencies, which may be required in some countries.
Document Type | Standard |
Status | Current |
Publisher | Standards Australia |
Committee | EL-015 |
Supersedes |
|