AS/NZS 4965.2:2008
AS/NZS 4965.2:2008
Performance of close control airconditioners Minimum energy performance standard (MEPS) requirements
Standards Australia
Performance of close control airconditioners Minimum energy performance standard (MEPS) requirements
Standards Australia
<toc>
<bookmarktable>
<bookmark index='0'>
<pageno>1</pageno>
<text>AS/NZS 4965.2:2008 PERFORMANCE OF CLOSE CONTROL AIRCONDITIONERS - MINIMUM ENERGY PERFORMANCE STANDARD (MEPS) REQUIREMENTS</text>
<bookmark index='1'>
<pageno>4</pageno>
<text>PREFACE</text>
</bookmark>
<bookmark index='2'>
<pageno>5</pageno>
<text>CONTENTS</text>
</bookmark>
<bookmark index='3'>
<pageno>6</pageno>
<text>SECTION 1 SCOPE AND GENERAL</text>
<bookmark index='4'>
<pageno>6</pageno>
<text>1.1 SCOPE</text>
</bookmark>
<bookmark index='5'>
<pageno>6</pageno>
<text>1.2 EXCLUSIONS</text>
</bookmark>
<bookmark index='6'>
<pageno>6</pageno>
<text>1.3 APPLICATION</text>
</bookmark>
<bookmark index='7'>
<pageno>6</pageno>
<text>1.4 OBJECTIVE</text>
</bookmark>
<bookmark index='8'>
<pageno>7</pageno>
<text>1.5 REFERENCED DOCUMENTS</text>
</bookmark>
<bookmark index='9'>
<pageno>7</pageno>
<text>1.6 DEFINITIONS</text>
<bookmark index='10'>
<pageno>7</pageno>
<text>1.6.1 Check test</text>
</bookmark>
<bookmark index='11'>
<pageno>7</pageno>
<text>1.6.2 Close control airconditioner</text>
</bookmark>
<bookmark index='12'>
<pageno>7</pageno>
<text>1.6.3 Rated total cooling capacity</text>
</bookmark>
<bookmark index='13'>
<pageno>7</pageno>
<text>1.6.4 Rated power</text>
</bookmark>
<bookmark index='14'>
<pageno>7</pageno>
<text>1.6.5 Supplementary equipment</text>
</bookmark>
<bookmark index='15'>
<pageno>7</pageno>
<text>1.6.6 Statements of intention</text>
</bookmark>
<bookmark index='16'>
<pageno>7</pageno>
<text>1.6.7 Three-phase model</text>
</bookmark>
<bookmark index='17'>
<pageno>8</pageno>
<text>1.6.8 Single-phase model</text>
</bookmark>
</bookmark>
<bookmark index='18'>
<pageno>8</pageno>
<text>1.7 MEASURED QUANTITIES</text>
</bookmark>
<bookmark index='19'>
<pageno>8</pageno>
<text>1.8 ROUNDING</text>
</bookmark>
</bookmark>
<bookmark index='20'>
<pageno>9</pageno>
<text>SECTION 2 PERFORMANCE CRITERIA</text>
<bookmark index='21'>
<pageno>9</pageno>
<text>2.1 GENERAL</text>
</bookmark>
<bookmark index='22'>
<pageno>9</pageno>
<text>2.2 MINIMUM ENERGY PERFORMANCE STANDARD</text>
</bookmark>
<bookmark index='23'>
<pageno>9</pageno>
<text>2.3 TEST CONDITIONS FOR DETERMINING MINIMUM ENERGY PERFORMANCE STANDARD</text>
</bookmark>
<bookmark index='24'>
<pageno>9</pageno>
<text>2.4 NUMBER OF TESTS AND PROCESSING OF DATA</text>
</bookmark>
<bookmark index='25'>
<pageno>9</pageno>
<text>2.5 MINIMUM ENERGY PERFORMANCE STANDARD REQUIREMENTS COMPLIANCE</text>
</bookmark>
<bookmark index='26'>
<pageno>10</pageno>
<text>2.6 STANDBY POWER AND CRANKCASE HEATERS</text>
</bookmark>
<bookmark index='27'>
<pageno>10</pageno>
<text>2.7 POWER FACTOR</text>
</bookmark>
</bookmark>
<bookmark index='28'>
<pageno>11</pageno>
<text>SECTION 3 APPLICATION AND TEST RESULT FORMATS</text>
<bookmark index='29'>
<pageno>11</pageno>
<text>3.1 APPLICATION FOR REGISTRATION</text>
<bookmark index='30'>
<pageno>11</pageno>
<text>3.1.1 General</text>
</bookmark>
<bookmark index='31'>
<pageno>11</pageno>
<text>3.1.2 Registration</text>
</bookmark>
<bookmark index='32'>
<pageno>11</pageno>
<text>3.1.3 Test report</text>
</bookmark>
<bookmark index='33'>
<pageno>11</pageno>
<text>3.1.4 MEPS transition</text>
</bookmark>
<bookmark index='34'>
<pageno>11</pageno>
<text>3.1.5 Duration of registration</text>
</bookmark>
</bookmark>
<bookmark index='35'>
<pageno>11</pageno>
<text>3.2 PRODUCT LISTING</text>
<bookmark index='36'>
<pageno>11</pageno>
<text>3.2.1 General</text>
</bookmark>
<bookmark index='37'>
<pageno>11</pageno>
<text>3.2.2 Data</text>
</bookmark>
<bookmark index='38'>
<pageno>12</pageno>
<text>3.2.3 Test report</text>
</bookmark>
<bookmark index='39'>
<pageno>12</pageno>
<text>3.2.4 MEPS transition</text>
</bookmark>
</bookmark>
<bookmark index='40'>
<pageno>12</pageno>
<text>3.3 DATE OF MANUFACTURE INFORMATION</text>
</bookmark>
</bookmark>
<bookmark index='41'>
<pageno>13</pageno>
<text>APPENDIX A - FORMAT OF APPLICATION FOR REGISTRATION OF AN AIRCONDITIONER FOR ENERGY LABELLING AND MEPS</text>
<bookmark index='42'>
<pageno>13</pageno>
<text>A1 INTRODUCTION</text>
</bookmark>
<bookmark index='43'>
<pageno>13</pageno>
<text>A2 SCOPE</text>
</bookmark>
<bookmark index='44'>
<pageno>13</pageno>
<text>A3 GUIDANCE ON THE USE OF THIS APPLICATION FORM</text>
<bookmark index='45'>
<pageno>13</pageno>
<text>A3.1 Submissions to the New Zealand regulator</text>
</bookmark>
</bookmark>
<bookmark index='46'>
<pageno>14</pageno>
<text>A4 APPLICATION FORM</text>
</bookmark>
</bookmark>
<bookmark index='47'>
<pageno>19</pageno>
<text>APPENDIX B - FORMAT OF SUMMARY TEST RESULTS FOR MEPS APPLICATION</text>
</bookmark>
</bookmark>
</bookmarktable>
</toc>
Specifies minimum energy performance standard (MEPS) requirements for close control airconditioners.
This Standard specifies the minimum energy performance standard (MEPS) requirements for close control airconditioners that fall in the scope of AS/NZS 4965.1.
This Standard does not specify electrical safety requirements.
This Standard specifies the following values for cooling, as applicable:
(a) Rated power (input).
(b) Rated capacity (output).
(c) Energy efficiency ratio (EERS) for cooling.
(d) Minimum energy performance standard requirements.
Document Type | Standard |
Status | Current |
Publisher | Standards Australia |
Committee | EL-015 |
Supersedes |
|