AS 2224.1-2009

AS 2224.1-2009

Medicine measures Glass

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Table of Contents

<toc>
<bookmarktable>
<bookmark index='0'>
<pageno>1</pageno>
<text>AS 2224.1-2009 MEDICINE MEASURES - GLASS</text>
<bookmark index='1'>
<pageno>4</pageno>
<text>PREFACE</text>
</bookmark>
<bookmark index='2'>
<pageno>5</pageno>
<text>CONTENTS</text>
</bookmark>
<bookmark index='3'>
<pageno>6</pageno>
<text>1 SCOPE</text>
</bookmark>
<bookmark index='4'>
<pageno>6</pageno>
<text>2 REFERENCED DOCUMENTS</text>
</bookmark>
<bookmark index='5'>
<pageno>6</pageno>
<text>3 DEFINITIONS</text>
<bookmark index='6'>
<pageno>6</pageno>
<text>3.1 Capacity at any graduation line</text>
</bookmark>
<bookmark index='7'>
<pageno>6</pageno>
<text>3.2 Permanently marked</text>
</bookmark>
<bookmark index='8'>
<pageno>6</pageno>
<text>3.3 Lead glass</text>
</bookmark>
</bookmark>
<bookmark index='9'>
<pageno>6</pageno>
<text>4 MATERIAL</text>
</bookmark>
<bookmark index='10'>
<pageno>7</pageno>
<text>5 DESIGN AND DIMENSIONS</text>
<bookmark index='11'>
<pageno>7</pageno>
<text>5.1 Design</text>
</bookmark>
<bookmark index='12'>
<pageno>7</pageno>
<text>5.2 Dimensions</text>
</bookmark>
</bookmark>
<bookmark index='13'>
<pageno>7</pageno>
<text>6 CONSTRUCTION</text>
<bookmark index='14'>
<pageno>7</pageno>
<text>6.1 General</text>
</bookmark>
<bookmark index='15'>
<pageno>7</pageno>
<text>6.2 Stability</text>
</bookmark>
<bookmark index='16'>
<pageno>7</pageno>
<text>6.3 Wall thickness</text>
</bookmark>
<bookmark index='17'>
<pageno>7</pageno>
<text>6.4 Pouring lip</text>
</bookmark>
<bookmark index='18'>
<pageno>7</pageno>
<text>6.5 Finish</text>
</bookmark>
</bookmark>
<bookmark index='19'>
<pageno>8</pageno>
<text>7 MARKINGS</text>
<bookmark index='20'>
<pageno>8</pageno>
<text>7.1 Calibration markings</text>
<bookmark index='21'>
<pageno>8</pageno>
<text>7.1.1 Scale marks</text>
</bookmark>
<bookmark index='22'>
<pageno>8</pageno>
<text>7.1.2 Graduation lines</text>
</bookmark>
<bookmark index='23'>
<pageno>8</pageno>
<text>7.1.3 Figures</text>
</bookmark>
<bookmark index='24'>
<pageno>8</pageno>
<text>7.1.4 Levelling line</text>
</bookmark>
</bookmark>
<bookmark index='25'>
<pageno>8</pageno>
<text>7.2 Other marking</text>
</bookmark>
</bookmark>
<bookmark index='26'>
<pageno>8</pageno>
<text>8 PERFORMANCE REQUIREMENTS</text>
<bookmark index='27'>
<pageno>8</pageno>
<text>8.1 Introduction</text>
</bookmark>
<bookmark index='28'>
<pageno>9</pageno>
<text>8.2 Sequence for conducting tests</text>
</bookmark>
<bookmark index='29'>
<pageno>9</pageno>
<text>8.3 Calibration accuracy</text>
</bookmark>
<bookmark index='30'>
<pageno>9</pageno>
<text>8.4 Stability</text>
</bookmark>
<bookmark index='31'>
<pageno>9</pageno>
<text>8.5 Resistance to leaching</text>
</bookmark>
<bookmark index='32'>
<pageno>9</pageno>
<text>8.6 Permanence of markings</text>
<bookmark index='33'>
<pageno>9</pageno>
<text>8.6.1 Introduction</text>
</bookmark>
<bookmark index='34'>
<pageno>10</pageno>
<text>8.6.2 Resistance to chemical agents</text>
</bookmark>
</bookmark>
<bookmark index='35'>
<pageno>10</pageno>
<text>8.7 Thermal shock resistance</text>
</bookmark>
</bookmark>
<bookmark index='36'>
<pageno>11</pageno>
<text>APPENDIX A - DETERMINATION OF RESISTANCE TO LEACHING</text>
<bookmark index='37'>
<pageno>11</pageno>
<text>A1 SCOPE</text>
</bookmark>
<bookmark index='38'>
<pageno>11</pageno>
<text>A2 PRINCIPLE</text>
</bookmark>
<bookmark index='39'>
<pageno>11</pageno>
<text>A3 REAGENTS</text>
<bookmark index='40'>
<pageno>11</pageno>
<text>A3.1 General</text>
</bookmark>
<bookmark index='41'>
<pageno>11</pageno>
<text>A3.2 Leaching solutions</text>
</bookmark>
<bookmark index='42'>
<pageno>11</pageno>
<text>A3.3 Standard lead solutions</text>
</bookmark>
</bookmark>
<bookmark index='43'>
<pageno>11</pageno>
<text>A4 TEMPERATURE OF TEST ENVIRONMENT</text>
</bookmark>
<bookmark index='44'>
<pageno>11</pageno>
<text>A5 PROCEDURE</text>
</bookmark>
<bookmark index='45'>
<pageno>12</pageno>
<text>A6 REPORT</text>
</bookmark>
</bookmark>
<bookmark index='46'>
<pageno>13</pageno>
<text>APPENDIX B - CHECK OF ACCURACY OF CALIBRATON</text>
<bookmark index='47'>
<pageno>13</pageno>
<text>B1 SCOPE</text>
</bookmark>
<bookmark index='48'>
<pageno>13</pageno>
<text>B2 PROCEDURE</text>
</bookmark>
<bookmark index='49'>
<pageno>13</pageno>
<text>B3 REPORT</text>
</bookmark>
</bookmark>
<bookmark index='50'>
<pageno>14</pageno>
<text>APPENDIX C - METHOD FOR ASSESSING RESISTANCE TO THERMAL SHOCK</text>
<bookmark index='51'>
<pageno>14</pageno>
<text>C1 SCOPE</text>
</bookmark>
<bookmark index='52'>
<pageno>14</pageno>
<text>C2 APPARATUS</text>
<bookmark index='53'>
<pageno>14</pageno>
<text>C2.1 Stopwatch</text>
</bookmark>
<bookmark index='54'>
<pageno>14</pageno>
<text>C2.2 Boiling water bath</text>
</bookmark>
<bookmark index='55'>
<pageno>14</pageno>
<text>C2.3 Water bath</text>
</bookmark>
<bookmark index='56'>
<pageno>14</pageno>
<text>C2.4 Pair of long-handled tongs</text>
</bookmark>
</bookmark>
<bookmark index='57'>
<pageno>14</pageno>
<text>C3 PROCEDURE</text>
</bookmark>
<bookmark index='58'>
<pageno>14</pageno>
<text>C4 REPORT</text>
</bookmark>
</bookmark>
<bookmark index='59'>
<pageno>15</pageno>
<text>APPENDIX D - METHOD FOR ASSESSING PERMANENCE OF MARKINGS</text>
<bookmark index='60'>
<pageno>15</pageno>
<text>D1 SCOPE</text>
</bookmark>
<bookmark index='61'>
<pageno>15</pageno>
<text>D2 PRINCIPLE</text>
</bookmark>
<bookmark index='62'>
<pageno>15</pageno>
<text>D3 REAGENTS</text>
</bookmark>
<bookmark index='63'>
<pageno>15</pageno>
<text>D4 APPARATUS</text>
<bookmark index='64'>
<pageno>15</pageno>
<text>D4.1 Constant temperature environment</text>
</bookmark>
<bookmark index='65'>
<pageno>15</pageno>
<text>D4.2 Test bath(s)/container(s)</text>
</bookmark>
<bookmark index='66'>
<pageno>16</pageno>
<text>D4.3 Control measure(s)</text>
</bookmark>
</bookmark>
<bookmark index='67'>
<pageno>16</pageno>
<text>D5 TEST PLAN</text>
<bookmark index='68'>
<pageno>16</pageno>
<text>D5.1 Preliminary considerations</text>
</bookmark>
<bookmark index='69'>
<pageno>16</pageno>
<text>D5.2 Choice of plan</text>
</bookmark>
</bookmark>
<bookmark index='70'>
<pageno>17</pageno>
<text>D6 PROCEDURE</text>
</bookmark>
<bookmark index='71'>
<pageno>18</pageno>
<text>D7 REPORT</text>
</bookmark>
</bookmark>
</bookmark>
</bookmarktable>
</toc>

Abstract

Specifies requirements for two types of glass medicine measure-one of tumbler form and one of conical form.

Scope

This Standard specifies requirements for two types of glass medicine measure - one of tumbler form and one of conical form.
NOTE: Pediatric droppers are not manufactured from glass.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
Committee CH-001
Supersedes
  • AS 2224.1-1986
  • DR 06226

Contact us