Specials

All specials

AS 4747.5-2013

AS 4747.5-2013

Meters for non-urban water supply Installation and commissioning of closed conduit meters fully charged

Standards Australia

More details

Download

PDF AVAILABLE FORMATS IMMEDIATE DOWNLOAD
$34.32

$78.00

(price reduced by 56 %)

Abstract

Sets out requirements for the installations of meters complying with AS 4747.2 for use in non-urban closed conduits applications.

Scope

This Standard sets out requirements for the installation of meters complying with NMI M 10-1 and AS 4747.2 for use in non-urban, closed conduit applications.
Two types of meter installations are covered in this Standard, as follows:
(a) A ‘self-contained unit’—a meter that defines its own geometry, is able to be pattern-approved as a complete water meter, calibrated upon assembly and supplied by a single supplier.
(b) A ‘modular metering system’—a device or group of instruments (which may be supplied as a pattern-approved metering system) that does not define the installation geometry and requires configuration after installation.
NOTE: The requirements for these types of meters to demonstrate compliance with this Standard, and hence with the National Framework are set out in AS 4747.2.
This Standard applies to meters that are—
(i) self-contained or modular and capable of continuously determining, within the accuracy limits, the volume of water that has flowed through them; and
(ii) continuously updating the volume on a cumulative basis.
NOTE: In this Standard a meter installation is considered to include—
(a) the meter, its indicating device and all ancillary equipment; and
(b) the upstream and downstream pipe or emplacement that may have a material effect on the meter unit.
This Standard applies to meters that operate under the following conditions:
(A) Closed conduit under full flow.
(B) Pressure range minimum 0.03 MPa to a value specified by the manufacturer. As a minimum, insertion or clamp-on meters will have the same working pressure range as the pipes they are designed to operate in.
(C) Working water temperature range of 0.1°C to 30°C. The maximum admissible temperature is 50°C, which is the limiting condition for the meter.
(D) Ambient air temperature range of ?5°C to 55°C.
(E) Ambient humidity range of 0% to 100% except for the remote indicating devices where the range is 0% to 93%.

General Product Information

Document Type Standard
Status Current
Publisher Standards Australia
Committee CE-024
Supersedes
  • DR AS 4747.5 CP
  • ATS 4747.5-2008

Contact us